Parameters in the file para.ini: advanced configuration
100 SAGEM
RT3000
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
16.24 AT command parameter
Can be configured by AT-command (see p. 62)
The settings you enter by AT commands are stored in the configuration file
para.ini
in
an own section.
This section is reserved.
16.25 Polarity reversal (Spain)
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
This function simulates the Polarity reversal feature provided on the Spanish fixed
telephone network, but there are some differences, caused by the adaptation to the
wireless environment.
Section:
DIALLING
Meaning
Parameter
Permitted Values Factory Setting
Polarity reversal
on/off on port A
CHA_POLARITY_REV YES,NO
NO
Polarity reversal
on/off on port B
CHB_POLARITY_REV YES,NO
NO
16.26 Hang-up delay
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
This function allows, in case of an incoming call to answer the call, to hang-up the call
and to continue the call, if you pick-up the phone again within the selected delay, if the
remote party has not yet terminate the call. This function is always active, if the
Polarity reversal has been activated. If the Polarity reversal function is off you may
activate the Hang-up delay by parameter.
Section:
DIALLING
Meaning Parameter
Permitted
Values
Factory Setting
Hang-up delay
on/off port A
CHA_MTC_HOOK_DELAY YES,
NO
NO
Hang-up delay port
A
CHA_MTC_HOOK_TIMEOUT 0....30000
6000 = 1min
Hang-up delay
on/off port B
CHB_MTC_HOOK_DELAY YES,
NO
NO