Procedure
Symptom
Test
Proc Sheet 4 01
myC5-2v, myC5-2m
5HPRYHDQG3ODFHWKH,2FRQQHFWRU
3/3
Before any operation,
-flux correctly the pins of the connector.
-with the solder wick loaded with tin , tin the pins of the
DATA/ AUDIO/ CHARGE connector by positioning it
straight ahead (pads upward), and by heating the solder
wick which is in touch with pins.
$WWHQWLRQ
- At the end of the operation , verify that there is no short
circuit between pads.
Start soldering the connector pins.
-Flux the place of the connector and position the DATA/
AUDIO/ CHARGE connector.
-Verify that the pins of the DATA/ AUDIO/ CHARGE
connector are well centred on pads.
-Heat pins with an air blow device while maintaining the
connector with tweezers
9HULI\WKDWWKHUHLVQRVKRUWFLUFXLWWKDWVROGHUVDUH
VKLQ\DQGWKDWWKH\FRYHUZHOOWKHSLQV
At last, solder the 4 pins crossing the board..
REF MTB DTS 1- Indice A - December 16 2005