VG5 SPECIFICATIONS (continued)
575V
*
HP ratings based on NEMA 4-pole motor data. However, when sizing a drive to match a motor, use output current ratings.
#
For proper operation, the motor rated current must be less than or equal to the inverter rated current.
** kVA ratings are based on 200V, 400V, and 600V inputs respectively.
Inverter Model
CIMR-G5U
VG5
51P5 52P2 53P7 55P5 57P5 5011 5015 5018 5022 5030 5037 5045 5055 5075 5090 5110 5160
Ou
tp
ut
Ch
ar
ac
te
ris
tic
s
Nominal Motor Output (HP) *
Constant
Torque 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200
Variable Torque 3 3 5 10 10 15 20 25 30 40 50 60 75 100 150 200 200
Capacity
(kVA)
**
2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200
Rated Output Current (A)
#
Constant
Torque
(A) 3.5 4.1 6.3 9.8 12.5 17 22 27 32 41 52 62 77 99 130 172 200
Variable
Torque
(A) 3.9 4.6 7 11 14 19 25 30 36 46 58 69 86 111 145 192 224
Maximum Voltage
3-Phase, 500/575/600V(Proportional to input voltage)
Rated Output Frequency
Up to 400 Hz available
Overload Capacity
150% Rated Current / 1 minute (CT rating)
120% Rated Current / 1 minute (VT rating)
Po
w
er
Su
pp
ly Input Current (A)
4.3 5.1 7.7 12.1 15.4 21 28 33 40 51 64 76 95 122 160 211 246
Rated Voltage & Frequency
3-Phase, 500 to 600V, 50/60Hz
Voltage Fluctuation
+10%, -15%
Frequency Fluctuation
±5%
Chapter 1 - Receiving & Installation
Specifications
Содержание CIMR-VG5
Страница 1: ...VG5 Series Revision F Installation Quick Start Manual General Purpose Flux Vector Inverter with AVC TM...
Страница 2: ...2 VG5 Installation Quick Start Manual This page intentionally left blank...
Страница 36: ...36 VG5 Installation Quick Start Manual This page intentionally left blank...
Страница 60: ...60 VSG5 Installation Quick Start Manual This page intentionally left blank...
Страница 113: ...VG5 Installation Quick Start Manual 113 This page intentionally left blank Appendix Notes...