SDC-620 Wiegand door controller 

 

 

 
Copyright© 2016 

– Saflec Systems (Pty) Ltd. 

http://www.saflecsystems.co.za 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 

Figure 2 

Possible position for an SDC-620 in a SACS access control system. 

 

 

Содержание SDC-620

Страница 1: ...ked using a protected RS 485 network The PC can connect to it using either RS 232 or the built in Ethernet connector or through the RS 485 network from another controller It has a reader RS 485 networ...

Страница 2: ...SDC 620 Wiegand door controller 2 Copyright 2016 Saflec Systems Pty Ltd http www saflecsystems co za Figure 2 Possible position for an SDC 620 in a SACS access control system...

Страница 3: ...wer the panel will be active If the screen is blank it will be in screen saving mode Tapping any button will awaken the screen and allow you to configure the device Figure 3 The configuration and diag...

Страница 4: ...ations network Each controller on this network requires a unique address for communications and identification Duplicate addresses will cause communication problems The address of the controller can b...

Страница 5: ...n the line by shorting J6 Controllers in the middle of the line must not have the termination jumper inserted as this can cause network problems In the diagram above you will see that the controller o...

Страница 6: ...mmunicate with the host system This can be done through either the Ethernet connection or the RS 232 connection The Ethernet cable is a non power over Ethernet cable to an RJ 45 plug The typical wirin...

Страница 7: ...oard with the power connector on the top right of the board the inputs are arranged in ascending order from left to right with a shared common between each input pair See the diagram below on how to c...

Страница 8: ...for the output relays Figure 12 Example wiring for an externally powered magnetic lock Normally closed Output mode 2 Internally powered outputs To set the output to internally powered mode place two j...

Страница 9: ...gand devices communicate with the SDC 620 via five signalling lines These lines can be broken into two groups The data lines Data 0 Data 1 The control lines Red LED Green LED and Buzzer Note Make sure...

Страница 10: ...interface front page It shows basic diagnostics information on the main page but the links at the bottom will require a username and password for authentication The default username is root and passwo...

Страница 11: ...contact Maximum voltage AC 250Vac Maximum voltage DC 220Vdc Internally powered Outputs Maximum combined current 3 7A Recommended maximums per relay 750mA at 12Vdc Externally powered Outputs Recommende...

Страница 12: ...SDC 620 Multiple door controller 12 Copyright 2016 Saflec Systems Pty Ltd http www saflecsystems co za Notes...