Product Specific Applications
Rescue / Confined Space:
The 019-11003 Confined Space System may be used in both Confined
Space and Rescue applications. Rescue systems function to safely remove a worker from a confined
space environment or after exposed to a fall. There are various configurations of rescue systems
depending on the type of rescue required. Structure must withstand loads applied in the directions
permitted by the system of at least 3,000 lbs. No free fall is permitted. Applicable D-rings are dorsal,
chest, and shoulder.
Lanyard Length
(6’ Total)
Deceleration
distance (4’ total)
Height of harness
dorsal D-ring from
worker’s feet
(6’ total)
Safety factor
(2’ total)
Required
distance
from
Anchorage
(18’ total)
Fall Clearance:
There must be sufficient clearance below the anchorage connector to arrest a fall
before the user strikes the ground or an obstruction. When calculating fall clearance, account for a
MINIMUM 2’ safety factor, deceleration distance, user height, length of lanyard/SRL, and all other
applicable factors. (See Figure 1)
Limitations
Fall Clearance Diagram
***Diagram shown is an example
fall clearance calculation ONLY.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-310 lbs
FIGURE 1