5.4
Ethernet switch statistics
Ethernet switch statistics window shows the full Ethernet statistics of CFIP switch since unit start
or statistics reset. All statistics are also accessible using command prompt command
ethernet
counters
<1|2|3|4|5|6|All|Clear>.
Explanation of fields:
1.
Shows the time during which statistics have been gathered;
2.
Clear statistics –
resets all statistics counters (not available for “guest” account);
3.
TxOctets
- The total number of good bytes of data transmitted by a port (excluding
preamble but including FCS);
4.
TxDropPkts
- This counter is incremented every time a transmit packet is dropped
due to lack of resources (e.g., transmit FIFO underflow), or an internal MAC sublayer
transmit error not counted by either the TxLateCollision or the TxExcessiveCollision
counters;
5.
TxQ0PKT
- The total number of good packets transmitted on COS0, which is
specified in MIB queue select register when QoS is enabled;
The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide • Rev. 1.10 •
© SAF Tehnika JSC 2013