12
12
System temperature fault
Temperature is out of defined range
13
13
No data from main PSU ADC
No data from the main PSU ADC
14
14
Main supply voltage failure
Main supply voltage is out of defined range
15
15
Main supply current failure
Main supply current is out of defined range
16
16
Main supply power failure
Main supply power is out of defined range
17
17
No data from power supply ADC
No data from ADC connected via I2C
interface
18
18
1,0V failure
Power supply voltage out of defined range
19
18
1,2V failure
Power supply voltage out of defined range
20
18
1,5V failure
Power supply voltage out of defined range
21
18
2,5V failure
Power supply voltage out of defined range
22
18
3,3V failure
Power supply voltage out of defined range
23
18
5,0V failure
Power supply voltage out of defined range
24
18
Permanent 7,5V failure
Power supply voltage out of defined range
25
18
Switchable 7,5V failure
Power supply voltage out of defined range
26
18
12,0V failure
Power supply voltage out of defined range
27
18
-5,0V failure
Power supply voltage out of defined range
28
19
No data from RADIO
No data from radio (for future
compatibility)
29
20
Rx level alarm
Rx alarm level is out of defined range
30
21
Tx PLL error alarm
Tx PLL failure
31
22
Rx PLL error alarm
Rx PLL failure
32
23
No data from MODEM
No data from MODEM connected via UART
interface
33
24
Acquire status alarm
Modem acquire failure status
34
25
Last acquire error status
Modem last acquire failure status
35
26
Radial MSE
Radial MSE is out of defined range
36
27
LDPC decoder stress
LDPC decoder stress is out of defined range
37
28
Tx ACM profile was changed
ACM profile was changed
38
29
RX carrier offset
Error in Rx carrier offset
39
30
No data from modem
temperature sensor
No data from modem temperature sensor
40
31
Modem temperature fault
Modem temperature is out of defined
range
41
32
ATPC Tx power correction was
changed
ATPC Tx power correction was changed
42
33
Rollback initiate system CPU
restart ==>
System restart was called by rollback [Only
rising]
43
34
System CPU reset was WDT
initiated ==>
System restart was called by watchdog
[Only rising]
44
35
PM log flash write error
Error while writing pm log to flash
The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide • Rev. 1.10 •