ROUBLESHOOTING
Fault
Cause
Solution
The fire does not burn well
Wood is too damp
Check, max. residual moisture 20%
Wrong fuel
Only use the permitted fuels for the appliance
Chimney draught too weak (min. 12 Pa)
Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Insufficient combustion air
Check air flow and diameter of flue connections
Check ventilation fittings and extractor hood, if
necessary open windows
Glass gets dirty quickly
Wood is too damp
Check, max. residual moisture 20%
Wrong fuel
Fuel not small enough, ensure max. size
Only use the permitted fuels for the appliance
Too much wood used
Do not use more 2 or 3 pieces of wood at once
Insufficient combustion air
Connect combustion air feed directly to the
appliance and extract to the circulation grid
or directly to outside
Check diameter of circulation
Check ventilation fittings and extractor hood, if
necessary open windows
There is a paint smell and smoke
The coating is drying out
There is a smell when the stove gets very hot.
Disappears after a while.
Condensation
Large temperature difference
Open the door a chink while the stove warms
up. Do not leave the appliance unattended!
Smoke nuisance
Chimney draught too weak (min. 12 Pa)
Check the outlet is airtight
Light fire in the chimney
Close any open doors on other appliances
connected to the chimney
Seal any cleaning hatches in the chimney
If necessary, clean the connector
Fuel is not entirely used up
Fuel should only be added when there is no
orange flame visible in the stove.
Chimney fire
Wrong fuel
Overloading
Poor maintenance
Shut off the air flow immediately and call the fire
brigade