S
AEY
FENIX
/
SAEY
FENIX
VITRO
810.6011.000 / 02
59
English
Zone 1 :
A chimney opening
is automatically
permitted
(preferably without
a static cowl)
Zone 2 :
A chimney opening is only permitted if the
appliance(s) is /are fitted with an
atmospheric burner and if a static cowl is
fitted to the top of the chimney..
Zone 3 :
A chimney opening
is not permitted
under any
circumstances.
For details on chimneys we refer you to the relevant regulations with which the chimney needs to
comply. Because of the highly technical nature of these regulations, they are primarily aimed at
professional installers/chimney specialists.
List of the most important standards with which chimneys have to comply:
- EN 12446:2003
Chimneys - Components - Concrete outer wall elements.
- EN 1443:2003
Chimneys - General requirements
- EN1856-1:2003
Chimneys - Requirements for metal chimneys - Part 1: System chimney
products
- EN1856-2:2004
Chimneys - Requirements for metal chimneys - Part 2: Metal liners and
connection flue pipes
- EN13384-1:2003
Chimneys - Thermal and fluid dynamic calculation methods - Part 1:
EN 2006
Chimneys serving one appliance
- EN1857: 2003
Chimneys - Components - Concrete flue liners
- EN1457: 1999 and Clay/ceramic flue liners. Requirements and test methods
En 2002
- EN 1806: 2006
Chimneys - Clay/ceramic flue blocks for single wall chimneys - Requirements
and test methods.
- EN13069: 2005
Chimneys - Clay/ceramic outer walls for system chimneys - Requirements
and test methods.
- EN 13063: 2006
Chimneys - System chimneys with ceramic flue liners - Part 1: Requirements
and test methods for soot fire resistance
For Belgium:
- NBN D51 parts 1, 2 and 3 installation standards for combustion appliances.
- NBN B61 parts 1, 2 and 3 rules governing the location of combustion appliances