background image

5

IDENTIFICATION OF EQUIPMENT

Description of Equipment

The Optilight Max is the latest generation of the appliances of photoactivation by LED light. This 

short name is the acronym for Light Emitting Diode, a totally different manner of emitting light, 

when compared with the conventional appliances of halogen light. As opposed to the traditional 

appliances, which generate light in a wide wave spectrum with great heat, this technology allows 

a cold light to be emitted, in the precise wavelength for activating the different dental products 

to which it applies.

LED technology, recently introduced in Dentistry, has brought countless advantages to the curing 

light appliances for direct restorations in composite resin. Besides being infinitely more durable, the 

LEDs have made the appliances more compact, ergonomic and easy to install and transport. The 

emission of cold light at a precise wavelength ensures the polymerization of composites activated 

by the canforoquinone, without risks of dental heating, pulpal injury or discomfort for operator 

and patients.

The safety and efficiency of the LEDs, now with high emission power, are available for all the clinical 

procedures which require power of light for photoactivation.

The wavelength of 420nm - 480nm associated with the high power emitted by the Optilight Max 

makes the multifunctionality of this appliance feasible:

• 

Direct restoring procedures: 

composite resins, ionomers and adhesives.

• 

Indirect restorations:

 adhesive cementing of laminates, inlays, esthetic pegs and metal-free crowns.

• 

Activation of photoactivated materials as sealers, surgical cements and lining bases.

Planned  and  built  using  cutting-edge  technology,  to  provide  results  within  the  specifications 

stipulated by the leading world dental authorities.

Endowed with an automatic bivolt switch power supply which allows one to use the equipment at 

any power supply voltage between 100 and 240V~ - 50/60Hz.

Digital control in the display on the handpiece itself.

Variance of choice of operating time (5,10,15 and 20 seconds).

It has 3 application modes: Continuous, Ramp and Pulsating:

 Continuous:

 Maximum and continuous mode of light intensity (same luminosity from start to 

finish of the polymerization).

• 

Ramp: 

Gradual mode of light intensity; it increases gradually.

 Pulsed:

 Pulsing mode consisting of cycles which oscillate at a fixed frequency.

Physical Principle used by the Equipment

The physical principle is the emission of a cold light to polymerize photosensitive substances, as the 

equipment is endowed with a cold light emitter (LED) with a wavelength between 420 and 480nm 

(blue light), which has an ideal intensity for being integrated with the canforoquinone.

Indication of the equipment

This equipment is exclusively for dental use, having to be employed and handled by a capacitated 

person (professional duly regulated, as per the local legislation of the country) observing the 

instructions contained in this manual.

The user is obliged to only use the equipment in perfect conditions and protect himself/herself, 

patients and third parties against possible hazards.

Purpose of the equipment

This equipment is exclusively for dental use, with the objective of polymerizing photosensitive 

substances through the emission of blue light.

It was developed to be used in several dental procedures such as: restoring procedures, bonding 

braces and activating photoactivated materials as sealers, lining bases.

Содержание Optilight Max

Страница 1: ......

Страница 2: ...a C N P J 55 979 736 0001 45 Insc Est 582 002 897 114 Rod Abr o Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeir o Preto S P Brasil Phone 55 16 3512 1212 Technical Duties Ricardo J Ravaneli CREA SP...

Страница 3: ...of use 21 Precautions and warnings during the installation of the equipment 21 Precautions and warnings during the use of equipment 22 Precautions and warnings after the use of equipment 22 Precautio...

Страница 4: ...ucts available in the World This manual is a general presentation of your product and it will give you important details to help you to solve possible problems Please read it and keep this with you ID...

Страница 5: ...and lining bases Planned and built using cutting edge technology to provide results within the specifications stipulated by the leading world dental authorities Endowed with an automatic bivolt switc...

Страница 6: ...rption interval of the photo starter therefore it s 100 used whereas the conventional equipment running on halogen lamps has non used wave length regions The Optilight Max doesn t generate heat since...

Страница 7: ...Shield 03 Control Panel 04 Handpiece 05 Button to turn on the equipment and activate interrupt operation 06 Charging base 07 Display Window 08 Time adjustment button 09 Application mode selection butt...

Страница 8: ...product verify the technical compatibility between the equipment coupling and accessories The use of any part accessory or material neither specified nor foreseen in those use operation instructions...

Страница 9: ...mer 5 10 15 and 20 seconds Time Sounder a beep every 05 seconds Activation Through the handpiece button Light Conductor Optics fiber 100 coherent which guarantees the passage of light without loss Han...

Страница 10: ...ion against harmful penetration of water IPX 0 Degree of saf ety of application in the presence of an anesthetic mixture inf lammable with air oxygen or nitrous oxide It is not suitable Battery of Li...

Страница 11: ...1 This Optilight Max uses RF energy only for internal functions However its emissions are too low and it s unlikely to cause any interference in the equipments next to it RF emissions ABNT NBR IEC CI...

Страница 12: ...kV lines s to ground It is advisable that the quality of the power supply should be that of hospital or typical commercial environment Reduction interruption and variance of voltage in power supply in...

Страница 13: ...itter as determined by means of electric inspection on sitea is less than the level of compliance in each frequancy rangeb There may be interference near the equipment marked with the following symbol...

Страница 14: ...rding to transmitter frequency M 150 kHz to 80 MHz d 1 2 p 80 kHz to 800 MHz d 1 2 p 800 kHz to 2 5 GHz d 2 3 p 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For tra...

Страница 15: ...15 Dimensions mm TECHNICAL SPECIFICATIONS...

Страница 16: ...exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Applied part type B General...

Страница 17: ...ource of 100V 240V 50 60Hz Connect the cable of the power supply source 12 to the charging base 06 and the power supply source 10 in the socket Insert the light conductor 01 in the handpiece 04 Remove...

Страница 18: ...ency The application mode chosen will be viewed in the sequence of LEDs 15 In order to schedule the time press the button 08 and choose the time 5 thru 20 seconds which will be viewed in the display 0...

Страница 19: ...imum power 1200 mW cm Tolerance is 200 mW cm ATTENTION Recharge the battery when one of the LED continuous ramp and pulsed are blinking Keep the handpiece in the charging base connected to the mains p...

Страница 20: ...ation This equipment must be transported and stored observing the following directions Avoid falls and impacts Keep it dry do not expose it to rain water drops or wet floor Keep it away from water and...

Страница 21: ...provided that the items of cleaning maintenance transportation and operation of this Manual are observed However an electromagnetic environment can interfere with its normal operation The equipment sh...

Страница 22: ...lity check if the problem is related to any item listed in the topic of unforeseen events failures causes and solutions If it is not possible to resolve the problem turn off the equipment remove the p...

Страница 23: ...leaning products or sodium hypochloride isn t recommended because they may damage the equipment Disinfection and sterilization Use clean and soft cloth dampened in alcohol 70 to disinfection of the eq...

Страница 24: ...ed to some of the listed items under the item Unpredictable situation cause and solution If it s not possible to solve the problem shutdown the equipment and demand the presence of a Saevo technician...

Страница 25: ...e The equipment is not polymerizing the resins Resin not appropriate for the wavelength range of the LED curing lights Light conductor fastened incorrectly Residue of resin in the light conductor Ligh...

Страница 26: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Страница 27: ...27...

Страница 28: ......

Отзывы: