PRECAUTIONS, RESTRICTIONS AND WARNINGS

Sensitivity to predictable environmental conditions in ordinary situations of 

use

- The equipment has been designed not to be sensible to interferences as magnetic fields, external 

electrical  influences,  electrostatic  discharges,  the  pressure  or  the  variation  of  pressure,  since 

the equipment is installed and kept clean, conserved, transported and operated conforming this 

operation instruction.

Precautions and warnings “during the use” of equipment

Precautions and warnings “during the installation” of the equipment

- Check the voltage of the equipment upon executing the electrical installation.

- Position the equipment in a place where it will not get wet.

- Install the equipment in a place where it will not be damaged by the pressure, temperature, 

humidity, direct sunlight, dust, salts, or sulfur compounds.

- The equipment must not undergo inclination, excessive vibrations, or blows (including during 

transportation and handling).

- This equipment was not planned for use in an environment where vapors, anesthetic mixtures 

inflammable with air, or oxygen and nitrous oxide can be detected.

-  Before  the  first  use  and/or  after  long  interruptions  from  work  such  as  vacations,  clean  and 

disinfect the equipment.

- This equipment is not sensitive to electrical, electrostatic and pressure interference, provided 

that the items of cleaning, maintenance, transportation and operation of this Manual are observed.

However, an electromagnetic environment can interfere with its normal operation.

- The equipment should only be operated by duly enabled and trained technicians (Dental Surgeons, 

Capacitated Professionals).

- If any maintenance should be required, only use services of the Saevo Authorized Technical 

Assistance.

- Do not expose the plastic parts to contact with chemical substances, use in the routines of dental 

treatment, such as: acids, mercury, acrylic liquids, amalgams, etc.

- Avoid the light conductor to terminal to touch the resin to be polymerized.

- When using the equipment check if the light conductor output doesn’t have residues that might 

obstruct the light beam.

-  Use  suitable  techniques  to  minimize  the  effects  of  the  contracting  of  the  photopolymerized 

material and also of the temperature in the region applied. These techniques consist of spacing 

proportional to the effect desired, i.e., withdrawing the tip from the activated region the power 

and temperature tend to diminish.

- A minimum distance of 10mm between the tip and the tooth is advisable.

Saevo shall not be responsible for:

- Use of the equipment differing from that for which it is intended.

- Damages caused to the equipment, the professional and/or the patient by the incorrect installation 

and erroneous procedures of maintenance, differing from those described in these 

Instructions for 

use which come with the equipment or by the incorrect operation of it.

Содержание Optilight Max

Страница 1: ......

Страница 2: ...a C N P J 55 979 736 0001 45 Insc Est 582 002 897 114 Rod Abr o Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeir o Preto S P Brasil Phone 55 16 3512 1212 Technical Duties Ricardo J Ravaneli CREA SP...

Страница 3: ...of use 21 Precautions and warnings during the installation of the equipment 21 Precautions and warnings during the use of equipment 22 Precautions and warnings after the use of equipment 22 Precautio...

Страница 4: ...ucts available in the World This manual is a general presentation of your product and it will give you important details to help you to solve possible problems Please read it and keep this with you ID...

Страница 5: ...and lining bases Planned and built using cutting edge technology to provide results within the specifications stipulated by the leading world dental authorities Endowed with an automatic bivolt switc...

Страница 6: ...rption interval of the photo starter therefore it s 100 used whereas the conventional equipment running on halogen lamps has non used wave length regions The Optilight Max doesn t generate heat since...

Страница 7: ...Shield 03 Control Panel 04 Handpiece 05 Button to turn on the equipment and activate interrupt operation 06 Charging base 07 Display Window 08 Time adjustment button 09 Application mode selection butt...

Страница 8: ...product verify the technical compatibility between the equipment coupling and accessories The use of any part accessory or material neither specified nor foreseen in those use operation instructions...

Страница 9: ...mer 5 10 15 and 20 seconds Time Sounder a beep every 05 seconds Activation Through the handpiece button Light Conductor Optics fiber 100 coherent which guarantees the passage of light without loss Han...

Страница 10: ...ion against harmful penetration of water IPX 0 Degree of saf ety of application in the presence of an anesthetic mixture inf lammable with air oxygen or nitrous oxide It is not suitable Battery of Li...

Страница 11: ...1 This Optilight Max uses RF energy only for internal functions However its emissions are too low and it s unlikely to cause any interference in the equipments next to it RF emissions ABNT NBR IEC CI...

Страница 12: ...kV lines s to ground It is advisable that the quality of the power supply should be that of hospital or typical commercial environment Reduction interruption and variance of voltage in power supply in...

Страница 13: ...itter as determined by means of electric inspection on sitea is less than the level of compliance in each frequancy rangeb There may be interference near the equipment marked with the following symbol...

Страница 14: ...rding to transmitter frequency M 150 kHz to 80 MHz d 1 2 p 80 kHz to 800 MHz d 1 2 p 800 kHz to 2 5 GHz d 2 3 p 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For tra...

Страница 15: ...15 Dimensions mm TECHNICAL SPECIFICATIONS...

Страница 16: ...exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Applied part type B General...

Страница 17: ...ource of 100V 240V 50 60Hz Connect the cable of the power supply source 12 to the charging base 06 and the power supply source 10 in the socket Insert the light conductor 01 in the handpiece 04 Remove...

Страница 18: ...ency The application mode chosen will be viewed in the sequence of LEDs 15 In order to schedule the time press the button 08 and choose the time 5 thru 20 seconds which will be viewed in the display 0...

Страница 19: ...imum power 1200 mW cm Tolerance is 200 mW cm ATTENTION Recharge the battery when one of the LED continuous ramp and pulsed are blinking Keep the handpiece in the charging base connected to the mains p...

Страница 20: ...ation This equipment must be transported and stored observing the following directions Avoid falls and impacts Keep it dry do not expose it to rain water drops or wet floor Keep it away from water and...

Страница 21: ...provided that the items of cleaning maintenance transportation and operation of this Manual are observed However an electromagnetic environment can interfere with its normal operation The equipment sh...

Страница 22: ...lity check if the problem is related to any item listed in the topic of unforeseen events failures causes and solutions If it is not possible to resolve the problem turn off the equipment remove the p...

Страница 23: ...leaning products or sodium hypochloride isn t recommended because they may damage the equipment Disinfection and sterilization Use clean and soft cloth dampened in alcohol 70 to disinfection of the eq...

Страница 24: ...ed to some of the listed items under the item Unpredictable situation cause and solution If it s not possible to solve the problem shutdown the equipment and demand the presence of a Saevo technician...

Страница 25: ...e The equipment is not polymerizing the resins Resin not appropriate for the wavelength range of the LED curing lights Light conductor fastened incorrectly Residue of resin in the light conductor Ligh...

Страница 26: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Страница 27: ...27...

Страница 28: ......

Отзывы: