NEW ROYAL
05 TROUBLESHOOTING
Saeco International Group
Rev. 01
Page / 07
5.1. Test mode
To enter Test Mode:
- Switch on the machine.
- Press the four function keys in the sequence indicated below (
SX3, SX2, SX4, SX1
) before the
initialization bar is completed.
Entry into Test Mode results in a screen divided into
sections, as illustrated in the diagram below
01
MENU
OK
ESC
SX1
DX1
SX2
DX2
SX3 SX4
DX3 DX4
BUTTON
MAIN FUNCTION
SECONDARY FUNCTION
SX1
Select ground/pre-ground
Menu access (hold down)
SX2
Espresso
SX3
Coffee
OK
SX4
Access to Special Menu
ESC
DX1
Clean cycle
Scroll menu up
DX2
Cappuccino
Scroll menu down
DX3
Latte macchiato
DX4
Entry to Stand-By
The sectors highlighted in yellow on the following screens represent the various loads that can be
activated by pressing the keys indicated in each sector.
This load is deactivated by pressing the same key once more.
The sectors highlighted in green provide information on the sensor status.
Other conditions in which a load can be automatically deactivated are:
- If a work cycle is defi ned and ends (e.g., coffee grinder or brewing unit).
- A time-out is reached (e.g.: 5 sec for the boiler test).
The symbols
can be activated with keys SX4 and DX1 and are used to navigate the Test
mode.
TITLE
SX1
INFO1
INFO5
INFO6
INFO7
INFO2
INFO3
INFO4
DX2
DX3
DX4
SX2
SX3
PartsGuru.com