English
11
127
11.2
Warning signals
This chapter describes all the warning messages that the machine may display to the user and the actions that can and/or
must be performed by the user.
Messages often come with symbolic images, in order to facilitate their understanding.
Sometimes the warning messages are just an image.
NB: (*) indicates that the message may affect either side of the machine.
Note: (**) indicates for the water NW version only
Warning signals
How to reset the function
NOTE
Refill water tank
Fill the water tank with fresh drinking water.
Err Flowmeter 1
Err Flowmeter 2
Group flowmeter error.
The sensor does not read enough pulses.
Perform a power OFF/ON to try to unblock the water circuit.
If the message persists please contact the customer support.
(*)
Error temp. Probe2
Boiler temperature sensor error group 2.
(*)
Error temp. Probe1
Boiler temperature sensor error group 1.
(*)
H2O Probe Error
Water boiler temperature sensor error.
Pressure Sensor Err
Pressure probe error.
Heating TimeOut 2
Slow heating of group 2 boiler.
Perform a power OFF / ON to reset the error.
If the message persists please contact the customer support.
(*)
Heating TimeOut 1
Slow heating of group 1 boiler.
Perform a power OFF / ON to reset the error.
If the message persists please contact the customer support.
(*)
TimeOut Heating H2O
Slow heating for water boiler.
Perform a power OFF / ON to reset the error.
If the message persists please contact the customer support.
TimeOut filling H2O
Steam boiler filling error.
Water boiler does not fill up.
Perform a power OFF / ON to reset the error.
Remove Coffee capsule
Empty the right/left capsule drawer.
(*)
INSERT BIN
Insert the left/right drip tray and capsule drawer into place.
(*)
OVER HEATING
Overheating protection.
Wait for the temperature to restore.
(*)
The right (2)/left (1) capsule drawer is reaching the maximum capacity of used
capsules.
The message is displayed 5 capsules before the shutdown.
Empty the capsule drawer asap.
(*)
Washing in progress.
Do not remove the
water tank
The machine is performing the rinse cycle.
Wait until the machine has completed the cycle.
The exclamation mark on the menu icon indicates an alarm.
For details enter the menu and view the notification area.
The machine requires a descaling cycle.
Contact the service provider.