37
English
8 - PURIFIER
REGENERATION
A
B
E
F
C
D
G
C
D
C
G
D
F
A
WATER INLET
B
WATER OUTPUT
C
INLET TAP LEVER
D
OUTPUT TAP LEVER
E
DEPRESSURIZER PIPE
F
REGENERATION TUBE
G
COVER KNOB
IMPORTANT
: Regenerate the purifier at the inter-
vals listed below:
- place the empty 2 litre container under pipe E.
- shift levers C and D from left to right as shown in fig.11.2
and remove the cover by loosening knob G, pour in 1.5
kg of sodium chloride (coarse cooking salt) into the 8-litre
purifier and 2 kg into the 12-litre type.
- Replace the lid and shift lever from right to left as shown
in fig.11.3 and allow the salted water to drain out of
pipe F until the water is fresh.
- Shift lever D from right to left as shown in fig.11.4
NB:
These regeneration instructions are valid only
providing the purifier is as that indicated in the
figures. Should it fail to correspond proceed
as indicated in the instructions attached to the
purifier itself.
Fig. 11.01
Fig. 11.02
Fig. 11.03
Fig. 11.04
HARDNESS °F
8 LITRE PURIFIER
12 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l.
regeneration after 1600 l
From 21 to 30
regeneration after 850 l.
regeneration after 1250 l.
From 31 to 40
regeneration after 650 l.
regeneration after 950 l.
From 41 to 50
regeneration after 450 l.
regeneration after 650 l.
Содержание AROMA COMPACT SE
Страница 24: ...Cod WGA8011011000 Rev 05...