CHS100.86.011 Rev.02 Date 23/07/2018
29
1009 MODE SELECTOR IN WRONG POSITION (SA100) (SHUTDOWN)
Mode selector SA100 was turned to a different position during the automatic cycle. The
machine immediately shuts down.
1010 SPACER GUARD (SQ42) (SHUTDOWN)
The guard of the cap spacer is open.
Make sure the guard is in the correct position and limit switch SQ42 works properly or is
properly connected.
1011 CHECK COMPRESSED AIR MAIN VALVE (SP1) (SHUTDOWN)
With the safety device in shutdown conditions, the system has not checked that the
compressed air circuit has actually been discharged.
Verify that valve YV100 works properly.
As this check is strictly related to operator safety, it is necessary to shut off the machine and
then turn it back on in order to reset the alarm.
1012 CHECK CAP INFEED IN THE TURN-PLATE (SQ53C) (SHUTDOWN)
No caps were detected in front of photocell SQ53C during the automatic cycle.
SQ53C input is permanently off or on.
Make certain sensor SQ53C is in the correct position and works properly.
1017 REJECT ON SPARK-TESTER ERROR (SHUTDOWN)
No ejected cap with defect detected by the Spark Tester was detected during the automatic
cycle.
Make sure solenoid valve YV30 is in the correct position and works properly.
Make certain sensor SQ11 is in the correct position and works properly
1018 OVERTURNED CONVEYOR BELT INVERTER (U25) CHECK (SHUTDOWN)
Inverter U25 shutdown was detected. Make sure there are no faults in the drive.
Make certain there are no mechanical obstructions that impede motor M25 from working
properly.