![Sacmi Imola CHS100 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/sacmi/imola-chs100/imola-chs100_instructions-manual_795368031.webp)
CHS100.86.011 Rev.02 Date 23/07/2018
31
2010 CHECK SPACER (SQ6) (STOPPAGE)
Sensor SQ6 malfunctioning was detected during the automatic cycle while the cap feed
starwheel (M13) was rotating.
SQ6 input is permanently off or on.
Make certain sensor SQ6 is in the correct position and works properly.
Make certain there are no mechanical obstructions that prevent M13 rotation.
2012 MAXIMUM LEVEL IN REJECT CONTAINER (SQ8) (STOPPAGE)
The maximum level of caps was found in the reject container during the automatic cycle.
Make sure photocell SQ8 is in the correct position and is properly set.
2013 OVERTEMPERATURE IN CVS COMPUTER (ST213) (STOPPAGE)
The temperature inside the CVS cabinet has been higher than the threshold set for
thermostat ST213 for 5 consecutive minutes.
Make sure air conditioner EV113 works efficiently.
Make certain thermostat ST213 is properly set and works efficiently.
2015 CHECK CAP INFEED IN THE FIRST CONVEYOR BELT (SQ53) (STOPPAGE)
No caps were detected in front of photocell SQ53 during the automatic cycle.
SQ53 input is permanently off or on.
Make certain sensor SQ53 is in the correct position and works properly.
2016 CHECK CAP INFEED IN THE TURN-PLATE (SQ53C) (STOPPAGE)
No caps were detected in front of photocell SQ53C during the automatic cycle.
SQ53C input is permanently off or on.
Make certain sensor SQ53C is in the correct position and works properly.
2018 CHECK SPARK-TESTER SETTING (STOPPAGE)
Before the cap piston was opened, the test sparks of the micro-hole control device (spark
tester) were not detected during the automatic cycle.
Make sure the spark tester operates efficiently and test voltage is properly set.
2019 TIME OUT, CAP FEED CHANNEL EMPTY (STOPPAGE)
If the feed channel is empty for more than 5 minutes during the automatic cycle, the machine
stops and the drive units stop too.
2020 MAXIMUM LEVEL IN OVERTURNED CONVEYOR BELT REJECT CONTAINER
(SQ8B) (STOPPAGE)
The maximum level of caps was detected in the overturned conveyor belt reject container
during the automatic cycle.
Make sure photocell SQ8B is in the correct position and is properly set.
2021 FIRST CONVEYOR BELT REJECT CONTAINER PRESENT CHECK (SQ9A)
(STOPPAGE)
The first conveyor belt reject container was not detected or not in the correct position during
the automatic cycle.
Make sure photocell SQ9A is in the correct position and is properly set.