CHS100.86.011 Rev.02 Date 23/07/2018
16
- COUNT DATA MENU
Number of caps/box
: this parameter may be used to set-up the desired number of caps for
each box. The box diverter is operated when the setpoint is reached.
The number of caps currently present in the box is displayed aside.
Cap diverter control is disabled when count is zero.
Cap count cannot be reset during the automatic cycle.
Length of box change pulse (KA1)
: setting regarding the duration of box pulse signal to
indicate box deviation to a downstream cartoning machine.
If the length is set to zero, the relay operation is bistable (one cycle ON and one cycle OFF)
Delay of box change signal
: length of time after which the downstream machine receives
the signal KA1. It indicates that the cap setpoint has been reached in the box.
Box change length
: time for box change length in the downstream machine is set. This
length of time controls the closing duration of the cap storage unit.
Vibration setpoint
: the number of caps between two activations of the box vibration signal
is set.
The signal control is disabled when the setpoint is zero.
Box vibration
: the activation time of the box vibration length is set.
Cap feed channel drained
: button used to activate the drainage of the cap feed channel.
This command is used to drain the feed channel. It is to be activated when the machine is
in automatic mode and stops the machine after drainage.