Page # 36
877 1st Ave. N.W. | Sioux Center, IA 51250 | Toll Free: 1.866.722.1488 | siouxautomation.com
OPERATION
REPLACEMENT PARTS
READ complete manual CAREFULLY
BEFORE attempting operation.
877 1st Ave. N.W. | Sioux Center, IA 51250 | Toll Free: 1.866.722.1488 | siouxautomation.com
OPERATION
REPLACEMENT PARTS
READ complete manual CAREFULLY
BEFORE attempting operation.
CONTROLS
Page | 17
522008
1
Warning: Front Hydro (1) System Pressure is Low.
Sensor OK! Check Hydro! High Speed Operation is
Disabled.
Check Hydro, oil level, and for
leaks. See Troubleshooting section
for details.
522008
3
Warning: Front Hydro (1) Pressure Sensor has High
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
Check sensor and wiring. Replace
as needed.
522008
4
Warning: Front Hydro (1) Pressure Sensor has Low
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
Check sensor and wiring. Replace
as needed.
522009
1
Warning: Rear Hydro (2) System Pressure is Low.
Sensor OK! Check Hydro! High Speed Operation is
Disabled.
Check Hydro, oil level, and for
leaks. See Troubleshooting section
for details.
522009
3
Warning: Rear Hydro (2) Pressure Sensor has High
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
Check sensor and wiring. Replace
as needed.
522009
4
Warning: Rear Hydro (2) Pressure Sensor has Low
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
Check sensor and wiring. Replace
as needed.
522010
14
Warning: Low Oil Level in Tank. Check for Leaks. Fill
Tank to Appropriate Level.
Check for leaks. Fill tank to
appropriate level.
522011
3
Warning: Aux 1 Pressure Sensor High Voltage. Check
sensors and wiring.
Check sensor and wiring. Replace
as needed.
522011
4
Warning: Aux 1 Pressure Sensor Low Voltage Output.
Check sensors and wiring.
Check sensor and wiring. Replace
as needed.
522012
3
Warning: Aux 2 Pressure Sensor High Voltage. Check
sensors and wiring.
Check sensor and wiring. Replace
as needed.
522012
4
Warning: Aux 2 Pressure Sensor Low Voltage Output.
Check sensors and wiring.
Check sensor and wiring. Replace
as needed.
522013
2
Warning: System Pressure is too High for High Speed
Operation. Unload Mixer until Pressure is Below
1500 PSI.
Unload mixer until system
pressure is below 1500 PSI.
522014
2
Warning: System Pressure Error. Augers Shifting back
to Low Speed Operation.
Check sensor and wiring. Replace
as needed.
522015
14
Warning: System Pressure is too High for High Speed
Operation. Shifting back to Low Speed.
Unload mixer until system
pressure is below 1500 PSI.
522016
3
Warning: Front Hydro 1 Coil Circuit is Open.
Check for loose wires and
connectors to front hydro coil.
522016
4
Warning: Front Hydro 1 Coil Circuit is Short Circuit to
Ground.
Check for shorted wires and
connectors to front hydro coil.
522017
3
Warning: Rear Hydro 2 Coil Circuit is Open.
Check for loose wires and
connectors to rear hydro coil.
522017
4
Warning: Rear Hydro 2 Coil Circuit is Short Circuit to
Ground.
Check for shorted wires and
connectors to rear hydro coil.
522018
3
High Speed Valve Coil is Open Circuit.
Check for loose or broken wires or
plugs to high speed valve coil.
522018
4
High Speed Valve Coil is Short Circuit to Ground.
Check for loose or broken wires or
plugs to high speed valve coil.
522019
3
Conveyor Motor Coil is Open Circuit.
Check for loose or broken wires or
plugs to conveyor valve coil.
522019
4
Conveyor Motor Circuit is Short Circuit to Ground.
Check for loose or broken wires or
plugs to conveyor valve coil.
Содержание 3600 Series