16
GB
16
TROUBLESHOOTING
Fault Possible
cause
Remedy
If the motor does not start 5
seconds after the unit is started
No power supply.
Connect the plug
C2
.
Check the fuse.
Power cable damaged.
Get it checked by an authorised workshop.
Cutting height has been set too low
(grass is too high and blocks the
starting of the motor).
Set a higher cutting height
I
.
Machine tilts when starting it.
Too much grass waste in the
housing.
Clean the cutting chamber of grass, ensure
that the gap between fan and housing is
kept clean (pull the plug first!).
Get it checked by an authorised workshop.
Extreme vibration
Have it checked by an authorized dealer
Unclean cut, lawn is yellow
Blade blunt.
Have it sharpened and balanced by an
authorized dealer
Q
.
Cutting height too low.
Adjust to higher cutting height
I
.
Mowing too fast.
Adjust mowing speed.
Insufficient overlapping of cuts when
mowing.
Tall grass conditions may dictate that more
overlapping of cuts is required.
Lawn becomes matted.
A lawn scarifier can remedy the problem
considerably
Ejection blocked
Turbo signal has not been detected
J
+
K
.
Empty the grass collector
L
.
Cutting height too low for grass that
is too high.
Adjust to higher cutting height
I
.
Pushing mower too fast.
Adjust mowing speed.
Grass not dry.
Let grass dry.
Mulched grass appearance is
poor:
clumps, excessive clippings,
rough cut.
Blade blunt.
Have it sharpened and balanced by an
authorized dealer.
Mulching rule not followed (cut max.
1/3 of the grass height; the height of
the grass to be cut must be lower
than 10 cm)
Adjust to higher cutting height
I
.
Convert mower to rear discharge
U2
+
S1
and mow grass first with higher cutting
setting.
Travel speed too fast.
Adjust travel speed.
Grass build-up under deck.
Adjust to higher cutting height
I
.
Insufficient overlapping of cuts when
mowing.
Tall grass conditions may dictate that more
overlapping of cuts is required
Grass not dry.
Adjust to higher cutting height
I
.
Let grass dry.
Repairs to electrical machines must always be performed only by qualified electricians. Please do not repair them yourself.
In the case of faults and defects which have not been listed here, please contact the nearest authorized dealer. This applies
in particular to appliances with electrical motors, as when these are repaired they must always undergo an insulation
protection test.
Your authorized dealer will also help you if you do not wish to perform any of the maintenance work described here yourself.
Содержание 36-EL
Страница 5: ......
Страница 6: ...A1 E1 B1 Q1 R1 S1...
Страница 7: ...I C2 D2 A2 F M...
Страница 12: ...U2 J K L O N...
Страница 13: ...Q S...
Страница 14: ......
Страница 82: ...2 RU 1 1 2 3 4 5 6 7 8 GS 9 10 11 12 CE 13 14 2 SABO SABO SABO Maschinenfabrik GmbH...
Страница 83: ...3 RU 3 DIN EN 60335...
Страница 84: ...4 RU 4 SABO 5 16...
Страница 85: ...5 RU H05 RN F H05 VV F DIN VDE 0282 4 3 x 1 DIN VDE 0620 230 16 30...
Страница 86: ...6 RU 30 15 C 1...
Страница 87: ...7 RU 3 3 11 4 6 2 12 H 05 RN F H05 VV F DIN VDE 0282 4 DIN EN 60335...
Страница 88: ...8 RU DIN EN 60335 DIN EN 60335 30 6 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 89: ...9 RU 7 A1 E1 B1 Z A1 E1 B1 B1 E1 B1 Q1 R1 S1 Q1 Q1 R1 R1 1 S1 I 3...
Страница 91: ...11 RU 5 1 2 3 4 5 6 10 F 3 11 3 12 3 1 S1 J K J K L...
Страница 92: ...12 RU 13 3 30 15 3 DIN EN 60335 10 32 32 BImSch V M 10 14...
Страница 93: ...13 RU DIN EN 60335 10 1 3 1 3 1 2...
Страница 94: ...14 RU U2 S1 U2 S1 14 10 50 1 15 3 O...
Страница 95: ...15 RU A1 Z A1 N N Q DIN EN 60335 1 Q 30...
Страница 96: ...16 RU DIN EN 60335 S 50 16 5 C2 I Q I...
Страница 97: ...17 RU J K L I 1 3 10 I U2 S1 I I...