55
Sabine 2.4 GHz Smart Spectrum
®
Wireless
LIT-SWM7000-OG-EN-070615.pmd - rr
© 2007 Sabine, Inc.
Appendix D: Dip Switch Settings
Channel
Center
Number
Frequency
1
2400.840000
2
2401.633469
3
2403.220408
4
2404.013878
5
2405.600816
6
2406.394286
7
2407.981224
8
2408.774694
9
2410.361633
10
2411.155102
11
2412.742041
12
2413.535510
13
2415.122449
14
2415.915918
15
2417.502857
16
2418.296327
17
2419.883265
18
2420.676735
19
2422.263673
20
2423.057143
21
2424.644082
22
2425.437551
23
2427.024490
24
2427.817959
Channel
Center
Number
Frequency
25
2429.404898
26
2430.198367
27
2431.785306
28
2432.578776
29
2434.165714
30
2434.959184
31
2436.546122
32
2437.339592
33
2438.926531
34
2439.720000
35
2441.306939
36
2442.100408
37
2443.687347
38
2444.480816
39
2446.067755
40
2446.861224
41
2448.448163
42
2449.241633
43
2450.828571
44
2451.622041
45
2453.208980
46
2454.002449
47
2455.589388
48
2456.382857
Channel
Center
Number
Frequency
49
2457.969796
50
2458.763265
51
2460.350204
52
2461.143673
53
2462.730612
54
2463.524082
55
2465.111020
56
2465.904490
57
2467.491429
58
2468.284898
59
2469.871837
60
2470.665306
61
2472.252245
62
2473.045714
63
2474.632653
64
2475.426122
65
2477.013061
66
2477.806531
67
2479.393469
68
2480.186939
69
2481.773878
70
2482.567347
Appendix E: Frequency Chart
Appendices
Front Panel Lock Status: LOCK 1 indicates all front panel controls are
locked to prevent intentional tampering, or accidental programming. LOCK
2 indicates a subset of controls are locked, allowing selected others to be
adjusted with software only. Default LOCK 2 setting locks out all functions
except FBX and Program Load. In addition, the LCD contrast control is not
locked in Lock 2.
(Located on the receiver back panel)
IMPORTANT: Dip Switches 1, 3, 4, & 8 must
always be in down position! The error mes-
sage to the right will display on the receiver if
the #1 dip switch is not in the down position.
NOTE 1: LOCK 1 overrides LOCK 2.
NOTE 2: Down is the default position.
NOTE 3: Lock settings are saved with the Pre-
sets.
Networking: The first receiver con-
nected to the PC must have dip switch
#7 set to the down position (default).
All other receivers connected within a
network must have dip switch #7 set to
the up position.
#
SERIES
DESCRIPTION
UP STATUS
DOWN STATUS
1
ALL
(Always Down)
Error
OK
2
ALL
FBX Filter Width
1/5 Octave
1/10 Octave
3
ALL
(Always Down)
Error
OK
4
ND
ONLY
Digital Output
External Word
(Default) Internal
Clock Source
Clock Input
Clock Source
5
ALL
Lock 1
Lock
Unlock
6
ALL
Lock 2
Lock
Unlock
7
ND
ONLY
Network Enable
Networked
No networking,
receivers
or 1st receiver in
other than 1st.
network.
8
ALL
(Always Down)
Error
OK
DIP SWITCH STATUS CHART