Saab TankRadar L/2
59
US Version. Seventh edition, June 1995
Installation Manual
T14
T13
T12
T3
T2
T1
L
D
DATUM
LEVEL
W11
W12
FOR
INTRINSICALLY
SAFE CIRCUITS
ONLY
"i"
Figure 14.1.
Installation of
temperature
sensors.
LPG/LNG. Enter if an Inclination Device will be used. If there is a
still pipe then enter the inner diameter and the type of pipe that
will be used.
Specify to which Field Communication Unit that each tank will be
connected. If there will be a Data Acquisition Unit connected at the
tank then specify if it will be a Slave or an Independent DAU and
if it will be equipped with a Local Readout LCD Display.
The number of digital outputs have to specified and if they are to
be normally ON or normally OFF.
The number of temperature sensors and their type (Cu 100 or Pt
100) has to be entered. Other inputs can be current inputs, fre-
quency inputs or digital inputs. Specify what kind of signal that is
read at the input. Please note the heights of the Resistance Tem-
perature Detectors in the tables on pages 6-8 in the appendix. See
also figure 14.1 below.