![Saab Marine Electronics TankRadar L/2 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/saab-marine-electronics/tankradar-l-2/tankradar-l-2_installation-manual_3135393029.webp)
Saab TankRadar L/2
29
US Version. Seventh edition, June 1995
Installation Manual
7.3
Junction Box JB 16 for Connection to RTG and Independent DAU
The JB 16 is an EEx "e" approved junction box, used for connecting
power and TRL/2 Bus to the RTG and the Independent DAU. It
contains 16 terminals, a flexible hose for the cabling to the RTG or
DAU, a mounting plate and various holes for glands from PG16-
21. Four glands are included for cable diameters 8-18 mm.
7.4
Junction Box JB 36 for Connection of Temperature Sensors
W11
W12
FOR
INTRINSICALLY
SAFE CIRCUITS
ONLY
"i"
~2 m wires with
protective hose
Independent
DAU
TH
6 pcs PG 21
JB 16 for
Relay Output
Signal
Power 230/115 V
~2 m wires
with
protective
hose
JB 16
JB 16
Saab Tank Control
TankRadar L/2
EEx ia II C T4
Tamb = -40
°
to +65
°
C
BASEEFAEx91C2069
Umax:in = 28 VDC Wmax:in = 1.3 W
Imas:in = 394 mADC
Ceq = 0 Leq = 0
Hazardous Location Class I Group A, B, C
and D. Temperature Code T4.
Intrinsically safe for use in connection
with Radar Unit TH 2000- TH 2014.
See control drawing 9150 057-901
Warning: any substitution of components
may impair intrinsic safety
See service manual
Ambient temperature -40
°
to +65
°
C
Serial no:
UI:
A division of Saab Marine Electronics AB
For intrinsically safe circuits only
Data Acquisition Unit Type DAU 2100
Listed 9390
UL
Ex
MADE IN SWEDEN
©
Figure 7.3 shows
the JB 16 junction
Box.
The JB 36 is used for the intrinsically safe connection of up to 14
temperature sensors to a DAU.
8
Connection to a Plant Host Computer (Plant DCS)
DAU
2 pcs PG 21
1 pc PG 16
Tempsensor
Pt100 - up to 12 sensors
Cu100 - up to 14 sensors
Cable
Saab Tank Control
TankRadar L/2
EEx ia II C T4
Tamb = -40
°
to +65
°
C
BASEEFAEx91C2069
Umax:in = 28 VDC Wmax:in = 1.3 W
Imas:in = 394 mADC
Ceq = 0 Leq = 0
Serial no:
UI:
A division of Saab Marine Electronics AB
For intrinsically safe circuits only
Data Acquisition Unit Type DAU 2130
Hazardous Location Class I Gorup C
and D. Temperature Code T4. The device
provides intrinsically safe outputs.
See control drawing 9150 057-901
Warning: any substitution of any components
may impair intrinsic safety.
See service manual
Ambient temperature -40
°
to +65
°
C
Listed 9390
UL
Ex
MADE IN SWEDEN
©
JB 36
DAU
2 pcs PG 21
1 pc PG 16
Tempsensor
Pt100 - up to 12 sensors
Cu100 - up to 14 sensors
Cable
Saab Tank Control
TankRadar L/2
EEx ia II C T4
Tamb = -40
°
to +65
°
C
BASEEFAEx91C2069
Umax:in = 28 VDC Wmax:in = 1.3 W
Imas:in = 394 mADC
Ceq = 0 Leq = 0
Serial no:
UI:
A division of Saab Marine Electronics AB
For intrinsically safe circuits only
Data Acquisition Unit Type DAU 2130
Hazardous Location Class I Gorup C
and D. Temperature Code T4. The device
provides intrinsically safe outputs.
See control drawing 9150 057-901
Warning: any substitution of any components
may impair intrinsic safety.
See service manual
Ambient temperature -40
°
to +65
°
C
Listed 9390
UL
Ex
MADE IN SWEDEN
©
JB 36
Figure 7.4 shows
two alternative
connections of the
JB 16 Junction Box.