Saab TankRadar L/2
47
US Version. Seventh edition, June 1995
Installation Manual
11.3 Installation of the Still Pipe Gauge, RTG 2940
Note:
If there is no flange on the still pipe a clamp flange must be
mounted.
Follow this step by step instruction when installing the Still Pipe
Gauge.
1.
Check that all parts and tools are available before carrying
them up to the tank top.
2.
Enter the Cone into the still pipe to make sure it fits. Maxi-
mum gap between the Cone and the pipe is 4 mm.
Flange
O-Ring
Cone
Flange
M16 screw and
washer
Spherical washers
O-Ring
Stand
Four screws
Flange
Cone
Stand
M16-screw
with
spherical
washers
3.
Mount the O-ring into the flange.
4.
Press the Flange onto the Cone. Use
manual force only. If there is much
resistance, try putting some grease
on the O-ring.
5.
Place the M16 screw with a washer
in the Stand. Fit the spherical wash-
ers onto the screw and secure these
washers by mounting the small O-
ring under the washers. This O-ring
can be left on when the Stand is
mounted onto the flange.
6.
Mount the Stand onto the Cone and
tighten the four screws.