page: 9
USER GUIDE
Update : 7/2/11
0Z NOT FR 0906
Vitrea
If you wish program several distributors in this mode, press briefly as much as necessary to reach the number
you chosen or do nothing if the chosen address is the following and, within 5 seconds, connect the distri-
butor which will get this new address and stabilize the display. Repeat this operation as much as necessary.
When you reach the n° " 9 ", the following number will be n° 1. After having addressed Distributor n° 9,
when you disconnect the distributor, the left digit display n° " 1 ". The current number blinks for 5 seconds
allowing eventually programming of the following distributor. If you do nothing, the Control Unit will exit
the programming mode after 5 seconds.
5.2/ Blanking
This procedure located on level " 4 " of the maintenance menus after the programming 3rd level allow to
erase one several distributors at the same time. You have just, Control Unit in the stop mode, to press
briefly 4 times on the yellow remote control to see the number "4" on the right digit. Press 2 seconds on
the yellow remote control to put all the distributors connected to their default address (virgin distributor
with the red LED lighting) and exit the blanking mode.
6.0/ Option : Alarm report
The alarm report is located on the contact 1 & 4 of the anti-displacement Plug
This is a dry N/O contact which is closed when there is a problem
This contact is activated in the following cases:
> Self-protection default
> Bus Default
> Sensors default
> Distributor Default
> Anti-displacement
> Connection of a TOR Sensor