- 10 - 

2. GENERAL

 

 
Fully automatic NG-L gas-fired warm air heater for 
stable  heating - equipped  with  infrared  flame 
monitoring,  electrical  ignition,  supporting  air 
blower,  and  open  combustion  chamber  for 
operation without an flue gas system. 
 
The unit can be converted to another gas type by 
means of nozzle change and pressure adjustment. 
 
 
 

3. SAFETY FEATURES

 

 
 

The WAH is equipped  with a safety temperature 
controller  (STC)  as  a  safety  feature  to  prevent 
overheating. 
 
The  STC  shuts  down  the  WAH  upon  exceeding 
the definitively set temperature. 
The integrated restart lock prevents restarting the 
WAH. 
 
After  cooling  the  WAH,  the  cause  must  be 
eliminated  and  the  STC  must  be  manually 
released.  The  reset  button  is  located  on  the 
switching  unit  under  the  black  screw  cap 
(Pos. 13). 
Then  press  reset  button  on  the  side  of  the 
switching unit (Pos. 15). 
 
The  built-in  infrared  flicker  sensor  serves  as  a 
flame  monitoring  device  and  is  connected  to  the 
automatic  gas  firing  unit  that  controls  and 
monitors the overall function of the WAH. 
 
 

4. INSTALLATION/ ASSEMBLY

 

 

In  order  to  prevent  personal  injury  and 
property  damage,  the  relevant  local  building, 
fire-prevention  and  professional  organization 
regulations 

must 

be 

unconditionally 

observed.

 

Before setting up it must be ensured that the 
local  supply  conditions  (gas  type,  pressure) 
and  the  current  setting  of  the  WAH 
correspond. 

 
The  WAH  should  be  operated  only  in  well-
ventilated  spaces  and  must 

not

  be  used  in 

residential or similar premises. 
 
To comply with the MAC limit values at the set-up 
location, for each KW of device output a fresh air 
exchange  rate  of  at  least  25  m

3

/h  must  be 

ensured.

 

 

Operation  in  environments  at  risk  of  fire  or 
explosion is 

prohibited

.

 

 

The WAH is freely horizontally suspended in the 
room  using  suitable  chains  connected  to  the 
three lugs provided for this purpose. 
Attachment of pipes, hoses or the like as well as 
changes  to  the  cross-section  is 

prohibited

  on 

the inlet and outlet side. 
 
It  must  be 

absolutely

  assured  that  there  is 

adequate distance from inflammable objects and 
structural  parts,  especially  on  the  exhaust  side 
and  this  must  be  verified  at  the  time  of  initial 
operation and further start-ups of the equipment. 

 

 
The  top,  bottom,  side  and  rear  safety  margins 

must  not  be  less  than  1.5  m.

  On  the  exhaust 

side, it must not be less than 10.0 m. 
 

 
 

Caution!!! 

 
WAH  electrical  and  gas  hook-ups  must  be 
done  only  by  a  specialist  and  in  accordance 

with local standards.  
 
Electrical Hook-up: 

 
The  electrical  hook-up  is  made  using  a  built-in 
power  cable  with  three-wire  grounded  plug  to  a 
230 V / 50 Hz a.c. power line. 
 

Gas Hook-up:

 

 
The WAH is factory – equipped with a G ¾“ inside 
thread  gas  hook-up.  With  NG-L-30  G  ½  “  inside 
thread. 
 
The  hook-up  to  the  gas  main  line  must  be  made 
using appropriate connectors. 
 
Since  there  may  be  regional  differences  in  gas 
composition, proper igniting must be checked on 
site  at  the  time  of  initial  operation  and  further 
start-ups. 
 
In  the  event  of  imperfect  ignition,  the  position  of 
the ignition electrode must be adjusted.  
These inspections should be repeated at regular 
intervals. 
 

Thermostat Connection:

 

 
The wiring of a room thermostat or of the floating 
contact  of  a  ventilation  control  can  connected  to 
the  existing  thermostat  plug-box  using  the 
appropriate plug. 
 
 
 
 

Содержание NG-L-100

Страница 1: ... 0 Betriebsanleitung Operating manuel Mode d utilisation Manual de instrucciones NG L 30 100 Gustav Nolting GmbH Neuzeitliche Heiztechnik ...

Страница 2: ...Inbetriebnahme Seite 4 6 Ausserbetriebnahme Seite 4 7 Wartungsarbeiten Seite 4 8 Umstellanleitung Seite 4 9 Mögliche Störungen und deren Ursachen Seite 5 10 Ersatzteilliste Seite 6 11 Elektrischer Schaltplan Seite 7 12 Bauteileübersicht Seite 29 31 ENGLISH Pages 8 14 FRANÇAIS Pages 15 21 ESPAÑOL Página 22 28 13 07 11 NG_L_EN_FR_ES_13 doc ...

Страница 3: ...0 0 80 0 100 0 Gasart Kategorie Erd und Flüssiggas II 2 E LL 3B P Anschlußdruck Erdgas Flüssiggas mbar 20 50 20 50 20 50 20 50 Anschlußwert kg h 2 33 3 89 6 23 7 78 Luftleistung m h 1 600 2 300 4 100 7 500 Elektroanschluß V Hz 230 50 230 50 230 50 230 50 Nennstrom A 0 85 1 0 2 9 2 7 Wurfweite m 30 40 50 60 Länge mm 990 990 1 150 1 250 Breite mm 445 510 560 640 Höhe mm 312 365 410 510 Gewicht kg 35...

Страница 4: ...men betrieben werden Um die MAK Grenzwerte im Aufstellungsort einzuhalten muß pro KW Geräteleistung eine Frischluftmenge von mindestens 25 m h gewährleistet sein Der Betrieb in feuer und explosionsgefährdeter Umgebung ist unzulässig Der WLE wird mittels geeigneter Ketten an den dafür vorgesehenen drei Ösen waagerecht frei im Raum aufgehängt Das Anbringen von Rohren Schläuchen o ä sowie Veränderung...

Страница 5: ...ie Betriebssicherheit zu gewährleisten und eine optimale Wirtschaftlichkeit zu erzielen muß der WLE in angemessenen Abständen gewartet und gereinigt werden Hierbei ist folgendes unbedingt zu beachten Bei Wartungsarbeiten den Netzstecker ziehen und die Gaszufuhr schließen Der WLE besonders der Infrarot Flackerdetektor Brenner die Zündelektrode und der Ventilator sind in angemessenen Zeitabständen a...

Страница 6: ...r hat nicht geschaltet Entriegeln bzw austauschen Austauschen Austauschen bzw Fremdlicht einfall verhindern Überprüfen WLE läuft an keine Zündung Magnetventil öffnet Gas strömt ein Störabschaltung Zündelektrode defekt Pos 7 Zündspalt zu groß Zündkabel defekt Pos 20 Gasfeuerungsautomat defekt Pos 14 Austauschen Verkleinern Austauschen Austauschen WLE läuft an Zündung ist vor handen Magnetventil öff...

Страница 7: ...7 10 Fühlerkabel für IRD 1020 100720 100720 100720 100720 11 Magnethalter für IRD 1020 100719 100719 100719 100719 12 Differenzdruckwächter 101300 101300 101300 101300 13 Sicherheitstemperaturbegrenzer STB 100219 100219 100219 100219 14 Gasfeuerungsautomat DVI 980 103946 103946 103946 103946 15 Entriegelungsknopf 103718 103718 103718 103718 16 Relais 100728 100728 100728 100728 17 Sicherung 101132...

Страница 8: ... 7 11 ELEKTRISCHER SCHALTPLAN Gerätetyp NG L 30 100 ...

Страница 9: ...ration and further start ups Page 11 6 Placing out of service Page 11 7 Maintenance Page 11 8 Conversion Instructions Page 11 9 Possible malfunctions and their causes Page 12 10 Spare Parts List Page 13 11 Electrical circuit diagrams Page 14 12 Components Overview Page 29 31 DEUTSCH Seite 1 7 FRANÇAIS Pages 15 21 ESPAÑOL página 22 28 ...

Страница 10: ...0 50 0 80 0 100 0 Gas type Category Natural gas and LPG II 2 E LL 3B P Connection pressure Natural gas LPG mbar 20 50 20 50 20 50 20 50 Connected load kg h 2 33 3 89 6 23 7 78 Air output m h 1 600 2 300 4 100 7 500 Electrical hook up V Hz 230 50 230 50 230 50 230 50 Rated current A 0 85 1 0 2 9 2 7 Blow m 30 40 50 60 Length mm 990 990 1 150 1 250 Width mm 445 510 560 640 Height mm 312 365 410 510 ...

Страница 11: ...ocation for each KW of device output a fresh air exchange rate of at least 25 m 3 h must be ensured Operation in environments at risk of fire or explosion is prohibited The WAH is freely horizontally suspended in the room using suitable chains connected to the three lugs provided for this purpose Attachment of pipes hoses or the like as well as changes to the cross section is prohibited on the inl...

Страница 12: ...tional reliability and to achieve optimum cost effectiveness the WAH must be serviced and cleaned at appropriate intervals When this is done the following must be observed When performing maintenance disconnect the power cord and close the gas supply The WAH especially the infrared flicker sensor burner and the blower must be checked at regular intervals for fouling and if necessary cleaned Do not...

Страница 13: ...pressure monitor did not trigger Reset or replace Replace Exchange or prevent impingement of external light Check WAH starts up no ignition solenoid valve opens gas flows in malfunction shutdown Ignition electrode defective Pos 7 Ignition gap to large Ignition cable defective Pos 20 Automatic gas firing unit defective Pos 14 Replace Reduce Replace Replace WAH starts up ignition present solenoid va...

Страница 14: ... 100217 10 Sensor cable for IRD 1020 100720 100720 100720 100720 11 Magnet holder for IRD 1020 100719 100719 100719 100719 12 Differential pressure monitor 101300 101300 101300 101300 13 Safety temperature controller STC 100219 100219 100219 100219 14 Automatic gas firing unit DVI 980 103946 103946 103946 103946 15 Release button 103718 103718 103718 103718 16 Relay 100728 100728 100728 100728 17 ...

Страница 15: ... 14 11 ELECTRICAL CIRCUIT DIAGRAM Device Type NG L 30 100 ...

Страница 16: ...Mise en service Page 17 6 Mise hors service Page 18 7 Maintenance Page 18 8 Instructions pour la commutation Page 18 9 Les dysfonctionnements possibles et leurs causes Page 19 10 Liste de pièces de rechange Page 20 11 Schéma des connexions électriques Page 21 12 Aperçu des composants Page 29 31 DEUTSCH Seite 1 7 ENGLISH Pages 8 14 ESPAÑOL página 22 28 ...

Страница 17: ...0 80 0 100 0 Type catégorie de gaz Gaz naturel et liquide II 2 E LL 3B P Pression du gaz à l entrée Gaz naturel et liquide mbar 20 50 20 50 20 50 20 50 Puissance connectée kg h 2 33 3 89 6 23 7 78 Volume d air débité m h 1 600 2 300 4 100 7 500 Raccordement au secteur V Hz 230 50 230 50 230 50 230 50 Courant nominal A 0 85 1 0 2 9 2 7 Longueur du jet m 30 40 50 60 Longueur mm 990 990 1 150 1 250 L...

Страница 18: ...s locaux semblables Un volume d air frais d au moins 25 m h doit être garanti par KW de puissance de l appareil afin de respecter la valeur limite de concentration maximale sur le poste de travail à l endroit de son emplacement Le fonctionnement dans les environnements à risque d incendie ou d explosion n est pas autorisé Le GAC est suspendu librement et horizontalement dans le local au moyen de c...

Страница 19: ...ne efficacité de fonctionnement optimales du GAC il est indispensable d effectuer régulièrement les travaux de maintenance et de nettoyage Veuillez impérativement observer les consignes suivantes Retirer la fiche mâle de la prise et fermer l alimentation de gaz avant d effectuer les activités de maintenance et de nettoyage Le GAC en particulier le détecteur infrarouge de scintillement le brûleur l...

Страница 20: ...ression différentielle ne s est pas mis en marche Déverrouiller respectivement remplacer Remplacer Remplacer respectivement éviter l exposition à une lueur externe Contrôler Le GAC démarre aucun allumage la vanne électromagnétique s ouvre le gaz entre arrêt de panne Electrode d allumage défectueuse Pos 7 Ecart d allumage trop grand Câble d allumage défectueux Pos 20 Le brûleur à gaz automatique es...

Страница 21: ...apteur pour IRD 1020 100720 100720 100720 100720 11 Support à aimant pour IRD 1020 100719 100719 100719 100719 12 l avertisseur à pression différentielle 101300 101300 101300 101300 13 Limiteur de sécurité de température LST 100219 100219 100219 100219 14 Commande automatique du brûleur à gaz DVI 980 103946 103946 103946 103946 15 Touche de déverrouillage 103718 103718 103718 103718 16 Relais 1007...

Страница 22: ... 21 11 SCHEMA DES CONNEXIONS ELECTRIQUES Version NG L 30 100 ...

Страница 23: ...cio Página 25 6 Puesta fuera de servicio Página 25 7 Trabajos de mantenimiento Página 25 8 Instrucciones para la adaptación Página 25 9 Averías posibles y sus causas Página 26 10 Lista de piezas de recambio Página 27 11 Esquema eléctrico Página 28 12 Visión general de los componentes Página 29 31 DEUTSCH Seite 1 7 ENGLISH Pages 8 14 FRANÇAIS Pages 15 21 ...

Страница 24: ...0 100 0 Tipo de gas categoría gas natural y gas licuado de petróleo II 2 E LL 3B P Presión de entrada gas natural licuado mbar 20 50 20 50 20 50 20 50 Consumo nominal kg h 2 33 3 89 6 23 7 78 Caudal de aire m h 1 600 2 300 4 100 7 500 Alimentación eléctrica V Hz 230 50 230 50 230 50 230 50 Corriente nominal A 0 85 1 0 2 9 2 7 Alcance del chorro de aire m 30 40 50 60 Largo mm 990 990 1 150 1 250 An...

Страница 25: ... es necesario que se suministre una cantidad de aire fresco mínima de 25 m h por cada kW de potencia del aparato Está prohibido hacer funcionar el WLE en zonas con peligro de explosión o incendio El WLE se eleva con ayuda de cadenas apropiadas que se sujetan a las tres corchetas previstas para ello de manera que el aparato quede suspendido libremente en el recinto de forma horizontal Queda prohibi...

Страница 26: ...al y lograr una rentabilidad óptima es necesario proceder en intervalos adecuados al mantenimiento y a la limpieza del WLE Obsérvense los siguientes puntos al respecto Desconectar el aparato de la red eléctrica y cerrar el suministro de gas antes de efectuar trabajos de mantenimiento Debe verificarse en intervalos adecuados el estado de limpieza del WLE en particular del detector de llama por infr...

Страница 27: ...oquear o sustituir Sustituir Sustituir o impedir la incidencia de la luz extraña Controlar El WLE arranca no hay encendido la válvula magnética se abre el gas entra desconexión por avería Electrodo de encendido defectuoso Pos 7 Distancia de encendido demasiado grande Cable de encendido defectuoso Pos 20 Centralita defectuosa Pos 14 Sustituir Reducir Sustituir Sustituir El WLE arranca el encendido ...

Страница 28: ...7 100217 100217 10 Cable de sensor para IRD 1020 100720 100720 100720 100720 11 Soporte magnético para IRD 1020 100719 100719 100719 100719 12 Manóstato diferencial 101300 101300 101300 101300 13 Limitador de temperatura de seguridad LTS 100219 100219 100219 100219 14 Centralita DVI 980 103946 103946 103946 103946 15 Botón de desbloqueo 103718 103718 103718 103718 16 Relé 100728 100728 100728 1007...

Страница 29: ... 28 11 ESQUEMA ELÉCTRICO Tipo de aparato NG L 30 100 ...

Страница 30: ... 29 NG L 30 NG L 50 2 7 20 19 8 22 21 8 22 20 7 21 19 2 6 6 ...

Страница 31: ... 30 NG L 100 22 19 8 21 20 7 6 1 2 3 NG L 80 7 20 22 19 8 2 6 NG L 80 7 20 22 19 8 2 6 ...

Страница 32: ... 31 14 15 5 11 12 9 17 10 NG L 30 100 16 4 18 13 ...

Страница 33: ...ie 90 396 EWG Applied EC direction Guideline for gas appliances 90 396 EC Maschinenrichtlinie 2006 42 EG Machine direction 2006 42 EC Niederspannungsrichtlinie 2006 95 EG Low voltage direction 2006 95 EC EMV Richtlinie 2004 108 EG EMV direction 2004 108 EC Angewandte harmonisierte Normen Applied harmonized standards DIN EN 12100 1 01 2003 Sicherheit von Maschinen Grundbegriffe allg Gestaltungsleit...

Страница 34: ...ferprogramm Warmlufterzeuger Anlagenbau Luftkanäle Gebläse für Traglufthallen und andere flexible Konstruktionen Steuerungsbau Stahlleichtbau Sondergerätebau Blechbearbeitung Our Comprehensive Supply Program Warm Air Heaters System Construction Air Ducts Fans for air supported domes and other flexible structures Control Systems Construction Light weight Steel Construction Special Equipment Constru...

Отзывы: