background image

6

 

Original instructions

 

| English

 

appliances are connected to the product, the engine will 

idle. If an appliance is added, the engine speed will increase 

to power the appliance. If the appliance is removed, the 

engine will return to idle.

CARRY HANDLES

The generator is equipped with two carry handles for 

easy transport. Both handles should be used to carry the 

generator.

ENGINE CHOKE/OFF SELECTOR KNOB

The engine choke/off selector knob is used when starting, 

stopping, and running the engine.

FUEL TANK

The fuel tank has a capacity of 4.5 L.

GROUND TERMINAL

The ground terminal is used to assist in properly grounding 

the generator to help protect against electric shock. Consult 

with a local electrician for grounding requirements in your 

area.

OIL CAP/DIPSTICK

Remove the oil fill cap to check and add oil to the generator 

when necessary.

PARALLEL KIT TERMINALS

The non-polarized parallel kit terminals are used with a 

parallel kit (sold separately) that will allow generators to be 

linked together to increase output.

NOTE:

 Read and understand the parallel kit’s instructions 

prior to use. The kit is for use with the RIG2000PCB only.

RESET BUTTON

The reset button is used to restore power if an overload 

occurs. To restore power, remove all attached load and 

depress the reset button.

LED DISPLAY

LEDs provide feedback to indicate whether the generator is 

in use, overloaded, or in need of lubricant.

RETRACTABLE HANDLE

The generator is equipped with a retractable handle that 

can be adjusted for storage and transportation.

USB OUTLETS

The two 5 Volt, 2.1 Amp max USB charging outlets will 

charge most USB-compatible devices.

STARTER GRIP AND ROPE

The starter grip and rope is used (along with the engine 

choke/off selector knob) to start the generator’s engine.

LOW OIL SHUT DOWN PROTECTOR

The low oil sensor causes the engine to stop if the level of 

lubricant in the crankcase is insufficient.

ASSEMBLY

UNPACKING

The product has been shipped completely assembled.

 

Remove one end of the box and carefully slide out the 

generator and any accessories. 

NOTE:

 The generator is heavy. If you must lift the 

product out of the box, get another person to help you; 

lift with your legs, not your back.

 

Inspect the product carefully to make sure no damage 

occurred during shipping.

 

Do not discard the packing material until you have 

 

carefully inspected and satisfactorily operated the 

 product.

 

If any parts are damaged or missing, take the product to 

an authorised service centre.

PACKING LIST

 

Generator

 

Engine lubricant (SAE 10W 30) (355 ml)

 

Paper funnel

 

Spark plug wrench

 

Operator’s manual

 

 WARNING

If any parts are damaged or missing, do not operate the 

product until the parts are replaced. Failure to heed this 

warning could result in serious personal injury.

 

 WARNING

Do not attempt to modify the product or create 

accessories not recommended for use with the product. 

Any  such  alteration  or  modification  is  considered  as 

misuse and could result in a hazardous condition leading 

to possible serious personal injury.

OPERATION

 

 WARNING

Carbon Monoxide

. Using a generator indoors can 

cause death in minutes.

Generator exhaust fumes contains high levels of carbon 

monoxide (CO), a poisonous gas you cannot see or smell. If 

you can smell the generator exhaust fumes, you are breathing 

CO. But even if you cannot smell the exhaust fumes, you 

could be breathing CO.

 

Never use a generator inside homes, garages, 

crawlspaces, or other partly enclosed areas. Deadly 

levels of carbon monoxide can build up in these areas. 

Using a fan or opening windows and doors does not 

supply enough fresh air.

 

Only use a generator outdoors and far away from open 

windows, doors, and vents. These openings can pull in 

generator exhaust fumes.

Содержание RIG2000PCB

Страница 1: ...RIG2000PCB ORIGINAL INSTRUCTIONS Digital Inverter Generator...

Страница 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Страница 3: ...erminal 9 Power indicator 10 Overload indicator 11 Low oil indicator 12 USB outlets 13 Auto idle on off button 14 Overload reset button 15 Retractable handle 16 Engine choke off selector knob 17 Start...

Страница 4: ...Fig 7 Fig 3 Fig 4 Fig 5 Fig 6 Fig 2 19 11 10 9 20 19 16 18 28 29...

Страница 5: ...Fig 9 Fig 9 Fig 8 Fig 10 Fig 11 Fig 12 Fig 13 4 23 22 21 20 24 25 26 18 24...

Страница 6: ...Fig 14 Fig 15 27 5 21 21 21 21...

Страница 7: ......

Страница 8: ...ls to use the product Protect children by keeping them at a safe distance from the generator set Do not start or operate the engine in a confined space building near open windows or in other unventila...

Страница 9: ...Operation of the generator at altitudes above 1 000 m may require retuning Consult a qualified service technician The generating set must not be connected to other power sources except another RIG2000...

Страница 10: ...ure that the oil cap is securely placed Gasoline fuel only Do not use diesel fuel WARNING Warning Hot surface Do not use the product indoors Only run the product outdoors Regulatory Compliance Mark RC...

Страница 11: ...red to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of th...

Страница 12: ...hing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator outp...

Страница 13: ...generator s engine LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient ASSEMBLY UNPACKING The product has been shipped c...

Страница 14: ...high charging current devices up to 2 1 A connect to the bottom USB port NOTE The USB oulets provides power only it does not provide any communication capabilities A suitable USB cable must be provid...

Страница 15: ...ce the engine choke off selector knob in the choke position Place the main on off switch in the on position Pull the engine recoil five 5 times to prime the fuel system Pull the recoil starter until t...

Страница 16: ...irt moisture or corrosive vapours Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves snow etc Do not use a garden hose to clean the generator Wa...

Страница 17: ...rchased Please contact your nearest service dealer for the location of the spark arrestor for your model To clean the spark arrestor Loosen the screws on the top panel Remove the top panel and set asi...

Страница 18: ...dB A 68 Noise level 7 m LpA dB A 63 Noise level LwA dB A 91 Storage time Before storing Less than 2 months Drain fuel from the tank and dispose of in a suitable container according to state and local...

Страница 19: ...uel Drain entire system and refuel with fresh unleaded fuel If problem continues have the product serviced by an authorised service centre The air filter is dirty Check the air filter Clean or replace...

Страница 20: ...ust idle speed n Check adjust valve clearance 1 n Clean fuel tank and filter 1 n Check fuel hose n n Fuel filter Inspect Replace Check all hose connections n n Inspect fuel tank vapor vent if equipped...

Страница 21: ...WIRING DIAGRAM...

Страница 22: ......

Страница 23: ......

Страница 24: ...orted by Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand 960478058...