background image

9

English |

 

Original instructions

 

Start the generator with nothing connected.

 

Plug in and turn on the first load, preferably the largest  

load (highest wattage) you have.

 

Permit the generator output to stabilise (engine runs  

smoothly and attached device operates properly).

 

Plug in and turn on the next load.

 

Again, permit the generator to stabilise.

 

Repeat previous two steps for each additional load.

 

 WARNING

Never add more loads than the generator capacity. 

Take special care to consider surge loads in generator 

capacity.

MOVING THE GENERATOR

See Figure 8.

 

Place the engine choke/off selector knob in the "off" 

position.

 

Allow 30 minutes of 'cool down' time before storing the 

product.

 

Pull the retractable handle out or carry by the carry 

handles.

 

Facing the front of the generator, grasp the folding 

handle firmly with one hand.

 

Lift the generator toward you until it balances on the 

wheels.

 

Turn around and pull the product along behind you to 

the desired location.

 

Lower the generator until it sits securely on a flat 

surface.

 

Secure the handle by pushing it all the way in.

HIGH ALTITUDE OPERATION

The product is not designed for high-altitude operation 

(altitudes greater than 600 m above sea level). Operating 

the product in higher altitudes may increase the engine’s 

emissions, decrease fuel economy and performance and 

reduce the generator life.

MAINTENANCE

 

 WARNING

When servicing, use only identical replacement parts. 

Use of any other parts could create a hazard or cause 

product damage.

 

 WARNING

Always wear eye protection with side shields. Failure to 

do so could result in objects being thrown into your eyes, 

resulting in possible serious injury.

Only the parts shown on the parts list are intended to be 

repaired or replaced by the customer. All other parts should 

be replaced at an authorised service centre.

GENERAL MAINTENANCE

Keep the generator in a clean and dry environment where it 

is not exposed to dust, dirt, moisture, or corrosive vapours. 

Do not allow the cooling air slots in the generator to become 

clogged with foreign material such as leaves, snow, etc.
Do not use a garden hose to clean the generator. Water 

entering the fuel system or other internal parts of the 

product can cause problems that will decrease the life of 

the generator.

To clean the product:

 

Use a soft bristle brush to loosen and remove dirt and 

debris.

 

Clean air vents with low pressure air that does not 

exceed 25 psi.

 

Wipe the exterior surfaces of the generator with a damp 

cloth.

CHECKING/CLEANING AIR FILTER

See Figures 9-10.

For proper performance and long life, keep air filters clean.

 

Loosen the screws on the side of the engine cover. 

Remove cover and set aside.

 

Loosen the screw in the centre of the air filter cover. 

Remove air filter cover and set aside.

 

Remove the air filter.

 

Wash the air filters with warm, soapy water. Rinse and  

squeeze to dry.

 

Reinstall the air filters.

NOTE:

 Make sure the filters are seated properly inside 

the generator. Installing the filters incorrectly will allow 

dirt to enter the engine, causing rapid engine wear.

 

Reinstall the air filter cover. Tighten the screw to secure.

 

Reinstall the engine cover. Tighten the knob to secure.

CHANGING ENGINE LUBRICANT

See Figure 11.

For best performance, engine lubricant should be changed 

after every 100 hours or 6 months of operation.

 

Loosen the knob at the side of the engine cover. 

Remove cover and set aside.

 

Remove the oil fill cap/dipstick.

 

Loosen the two screws and remove the oil drain cover.

 

Tilt the generator to the side and allow lubricant to drain 

from the oil fill hole into an approved container.

 

NOTE:

 Drain the lubricant while the engine is still warm 

but not hot. Warm lubricant will drain quickly and more 

completely.

 

 WARNING

Do not change engine lubricant while it is hot. Accidental 

contact with hot engine lubricant could result in serious 

burns.

 

Return the generator to an upright position and 

refill with lubricant following the instructions in the 

"Checking/Adding Lubricant" section in this manual. For 

amount of lubricant needed to refill, see the "Product 

Содержание RIG2000PCB

Страница 1: ...RIG2000PCB ORIGINAL INSTRUCTIONS Digital Inverter Generator...

Страница 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Страница 3: ...erminal 9 Power indicator 10 Overload indicator 11 Low oil indicator 12 USB outlets 13 Auto idle on off button 14 Overload reset button 15 Retractable handle 16 Engine choke off selector knob 17 Start...

Страница 4: ...Fig 7 Fig 3 Fig 4 Fig 5 Fig 6 Fig 2 19 11 10 9 20 19 16 18 28 29...

Страница 5: ...Fig 9 Fig 9 Fig 8 Fig 10 Fig 11 Fig 12 Fig 13 4 23 22 21 20 24 25 26 18 24...

Страница 6: ...Fig 14 Fig 15 27 5 21 21 21 21...

Страница 7: ......

Страница 8: ...ls to use the product Protect children by keeping them at a safe distance from the generator set Do not start or operate the engine in a confined space building near open windows or in other unventila...

Страница 9: ...Operation of the generator at altitudes above 1 000 m may require retuning Consult a qualified service technician The generating set must not be connected to other power sources except another RIG2000...

Страница 10: ...ure that the oil cap is securely placed Gasoline fuel only Do not use diesel fuel WARNING Warning Hot surface Do not use the product indoors Only run the product outdoors Regulatory Compliance Mark RC...

Страница 11: ...red to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of th...

Страница 12: ...hing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator outp...

Страница 13: ...generator s engine LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient ASSEMBLY UNPACKING The product has been shipped c...

Страница 14: ...high charging current devices up to 2 1 A connect to the bottom USB port NOTE The USB oulets provides power only it does not provide any communication capabilities A suitable USB cable must be provid...

Страница 15: ...ce the engine choke off selector knob in the choke position Place the main on off switch in the on position Pull the engine recoil five 5 times to prime the fuel system Pull the recoil starter until t...

Страница 16: ...irt moisture or corrosive vapours Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves snow etc Do not use a garden hose to clean the generator Wa...

Страница 17: ...rchased Please contact your nearest service dealer for the location of the spark arrestor for your model To clean the spark arrestor Loosen the screws on the top panel Remove the top panel and set asi...

Страница 18: ...dB A 68 Noise level 7 m LpA dB A 63 Noise level LwA dB A 91 Storage time Before storing Less than 2 months Drain fuel from the tank and dispose of in a suitable container according to state and local...

Страница 19: ...uel Drain entire system and refuel with fresh unleaded fuel If problem continues have the product serviced by an authorised service centre The air filter is dirty Check the air filter Clean or replace...

Страница 20: ...ust idle speed n Check adjust valve clearance 1 n Clean fuel tank and filter 1 n Check fuel hose n n Fuel filter Inspect Replace Check all hose connections n n Inspect fuel tank vapor vent if equipped...

Страница 21: ...WIRING DIAGRAM...

Страница 22: ......

Страница 23: ......

Страница 24: ...orted by Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand 960478058...

Отзывы: