background image

1

English |

 

Original instructions

Safety, performance, and dependability have been given 

top priority in the design of your digital inverter generator.

INTENDED USE

The generator is designed to supply electrical power for 

operating compatible electrical lighting, appliances, tools, 

and motor loads.
Do not use the product to provide power for emergency 

medical equipment or life support devices.
Do not use the product to jump start vehicles. Doing so 

could result in damage to the vehicle or its electrical 

components.
Do not use the product for any other purpose.

IMPORTANT SAFETY INSTRUCTIONS

 

 DANGER

Carbon Monoxide

. Using a generator indoors can 

cause death in minutes.
Generator exhaust contains high levels of carbon 

monoxide (CO), a poisonous gas you cannot see or 

smell. If you can smell the generator exhaust, you are 

breathing CO. But even if you cannot smell the exhaust, 

you could be breathing CO.

 

Never use the generator inside homes, garages, 

crawlspaces, or other partly enclosed areas. Deadly 

levels of carbon monoxide can build up in these areas. 

Using a fan or opening windows and doors does not 

supply enough fresh air.

 

Only use the generator outdoors and far away from 

open windows, doors, and vents. These openings can 

pull in generator exhaust.

Even when you use the generator correctly, CO may leak 

into your home. Always use a battery-powered or battery-

backup CO alarm in your home.
If you start to feel sick, dizzy, or weak after the generator 

has been running, move to an area with fresh air right 

away. See a physician. You could have a carbon monoxide 

poisoning.

 

 WARNING

Read and understand all instructions

. Failure to 

follow the warnings and instructions may result in electric 

shock, fire, and/or carbon monoxide poisoning, which 

will cause death or serious injury.

 

 WARNING

Before using the ground terminal, consult a qualified 

electrician to comply with the intended use of the 

 generator.

Do not use the product in flammable surroundings.

Save these instructions.

This manual contains important instructions that should 

be followed during the installation and maintenance of the 

product.

 

Do not allow children or untrained individuals to use 

the product. Protect children by keeping them at a safe 

distance from the generator set.

 

Do not start or operate the engine in a confined space, 

building, near open windows, or in other unventilated 

space where dangerous carbon monoxide fumes can 

collect. Carbon monoxide, a colorless, odorless, and 

extremely dangerous gas, can cause unconsciousness 

or death.

 

Never start or run the engine inside a closed or partially 

enclosed area. Breathing exhaust fumes will kill you.

 

Keep all parts of your body away from any moving parts 

and all hot surfaces of the product.

 

Wear eye protection as well as hearing protection when 

operating the product.

 

Wear sturdy and dry shoes or boots. Do not operate 

while barefoot.

 

Keep all bystanders, children, and pets at least 3 m 

away.

 

Do not operate the product when you are tired or under 

the influence of drugs, alcohol, or medication.

 

Product users in some countries must comply with fire 

prevention regulations. The product is equipped with a 

spark arrestor.

 

Do not touch bare wires or 240 V outlets.

 

Before each use, make sure to check the generator 

wiring, outlets, and connectors for damage. You should 

not use the product if any of these parts are damaged.

 

To reduce the risk of fire and burn injury, handle fuel 

with care. It is highly flammable.

 

Do not smoke while handling fuel or when filling the 

generator with fuel. Do not refuel when near naked 

flames.

 

Do not refuel the product while operating. Position the 

product on level ground, stop engine, and allow the 

product to cool down before refuelling.

 

Do not smoke when mixing fuel or filling fuel tank.

 

Mix and store fuel in a container approved for fuel.

 

Mix fuel outdoors where there are no sparks or 

flames. Wipe any fuel spillage. Move 9 m away from 

refuelling site before starting engine.

 

Stop the engine and allow the product to cool down 

before refuelling or storing the product.

 

Allow the engine to cool down; empty the fuel 

tank and secure the product from moving before 

transporting in a vehicle.

 

Generators vibrate in normal use. During and after the 

use of the generator, inspect the generator as well as 

extension cords and power supply cords connected to it 

for damage resulting from vibration. Have the damaged 

items repaired or replaced as necessary. Do not use 

plugs or cords that show signs of damage such as 

broken or cracked insulation.

Содержание RIG2000PCB

Страница 1: ...RIG2000PCB ORIGINAL INSTRUCTIONS Digital Inverter Generator...

Страница 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification...

Страница 3: ...erminal 9 Power indicator 10 Overload indicator 11 Low oil indicator 12 USB outlets 13 Auto idle on off button 14 Overload reset button 15 Retractable handle 16 Engine choke off selector knob 17 Start...

Страница 4: ...Fig 7 Fig 3 Fig 4 Fig 5 Fig 6 Fig 2 19 11 10 9 20 19 16 18 28 29...

Страница 5: ...Fig 9 Fig 9 Fig 8 Fig 10 Fig 11 Fig 12 Fig 13 4 23 22 21 20 24 25 26 18 24...

Страница 6: ...Fig 14 Fig 15 27 5 21 21 21 21...

Страница 7: ......

Страница 8: ...ls to use the product Protect children by keeping them at a safe distance from the generator set Do not start or operate the engine in a confined space building near open windows or in other unventila...

Страница 9: ...Operation of the generator at altitudes above 1 000 m may require retuning Consult a qualified service technician The generating set must not be connected to other power sources except another RIG2000...

Страница 10: ...ure that the oil cap is securely placed Gasoline fuel only Do not use diesel fuel WARNING Warning Hot surface Do not use the product indoors Only run the product outdoors Regulatory Compliance Mark RC...

Страница 11: ...red to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of th...

Страница 12: ...hing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator outp...

Страница 13: ...generator s engine LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient ASSEMBLY UNPACKING The product has been shipped c...

Страница 14: ...high charging current devices up to 2 1 A connect to the bottom USB port NOTE The USB oulets provides power only it does not provide any communication capabilities A suitable USB cable must be provid...

Страница 15: ...ce the engine choke off selector knob in the choke position Place the main on off switch in the on position Pull the engine recoil five 5 times to prime the fuel system Pull the recoil starter until t...

Страница 16: ...irt moisture or corrosive vapours Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves snow etc Do not use a garden hose to clean the generator Wa...

Страница 17: ...rchased Please contact your nearest service dealer for the location of the spark arrestor for your model To clean the spark arrestor Loosen the screws on the top panel Remove the top panel and set asi...

Страница 18: ...dB A 68 Noise level 7 m LpA dB A 63 Noise level LwA dB A 91 Storage time Before storing Less than 2 months Drain fuel from the tank and dispose of in a suitable container according to state and local...

Страница 19: ...uel Drain entire system and refuel with fresh unleaded fuel If problem continues have the product serviced by an authorised service centre The air filter is dirty Check the air filter Clean or replace...

Страница 20: ...ust idle speed n Check adjust valve clearance 1 n Clean fuel tank and filter 1 n Check fuel hose n n Fuel filter Inspect Replace Check all hose connections n n Inspect fuel tank vapor vent if equipped...

Страница 21: ...WIRING DIAGRAM...

Страница 22: ......

Страница 23: ......

Страница 24: ...orted by Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand 960478058...

Отзывы: