QUICK USE MANUAL 68090258
ORIGINALE
RUTHMANN ITALIA s.r.l. Via Santa Maria del Piano di Sotto, 91/B - 47854 Montescudo – Monte Colombo (RN) – ITALIA
pagina 15
“WARMING MESSAGE”/ “ALARM MESSAGE”
During the use of platform on first line of screen could appears a “Warming Message” following a not
correct use or a “Alarm Message” on malfunctioning of platform devices:
WARMING MESSAGE
1
'Please lift the upper boom'
5
‘Platform automatic closing'
2
'Automatic opening of the jib'
6
'Center basket for automatic closing!'
3
'Open the jib or lift the upper boom'
7
'Only 3 outriggers on the ground!'
4
'Lift the lower or the upper boom'
8
'Re-press pedal / close emergency cover'
ALARM MESSAGE
1
' Angle sensor A is not transmitting!'
16 'Joystick 3 gangplank damaged!'
2
'Angle sensor B is not transmitting!'
17 'Joystick 4 gangplank damaged!'
3
'Differential angle sensors on the X axis!'
18 'Joystick 5 gangplank damaged!'
4
'Differential angle sensors on the Y axis!'
19 'Joystick 6 gangplank damaged!'
5
'Overload on load cell channel 1!'
20 'Pins lock stabilizers not fixed!'
6
'Overload on load cell channel 2!'
21 'Chains of telescope broken!'
7
'Differential on load cell!'
22 'High lateral chassis inclination!'
8
'Pressure sensor A is not transmitting!!'
23 'Malfunction switches closed arm!'
9
'Pressure sensor B is not transmitting!!'
24 'Malfunction switches jib!'
10 'Pressure sensor C is not transmitting!!'
25 'Booms not completely closed'
11 'Pressure sensor D is not transmitting!!'
26 'Outreach more than the maximum allowed!'
12 'Differential pressure sensors A-B!'
27 'Raise the tracks from the ground!'
13 'Differential pressure sensors C-D!'
28 'Error on stabilizers switch!'
14 'Joystick 1 gangplank damaged!'
29 'Error on relief pressure switch!'
15 'Joystick 2 gangplank damaged!'
30 'Error on stabilizers pressure switch!'