RUNLUCKY SHOWER SOFTENER
13
Installed after water heater,
meter type
installation type selection, press
to select
the type, then press
to save the setting
and quit.
Installed before water
heater, meter type
Enquiry mode:Power on, interface will display installation type.
6.4. Regeneration Days Reminding Settings
The shower softener can be set up alarm of regeneration days according to the practical circumstance.
The screen flashes to remind the ender user to add salt. Under the time clock mode, press and hold
button to enter into the interface of setting regeneration days reminding. Press
to set the days, then
press
to save the setting and quit. For example, if it is set 07, 7 days after regeneration, the screen
flashes to remind the ender user to add salt. The default setting is 00 which means no reminding.
6.5. Meaning of Running Code
Code
Meaning
Explaination
Code
Meaning
Explaination
Service/ Service
Days
Fast Rinse
Water flows out
from drain
Backwash
Water flows
out from drain
Salt Disslution
Salt Disslution
Fast Rinse
Water flows out
from drain
Fast Rinse
Water flows
out from drain
Closing and
Waiting
Salt Disslution
7. Trouble Shooting
Problem
Cause
Correction
Leakage
No o-ring installed or assembly
not tight.
Install o-ring and tighten the
connection.
Water flow rate
decreased
Strainer blocked.
Clean strainer and install front filter
screen.
Outlet water
unqualified
1.Resin invalid.
2.Resin lifetime expired.
3.Regeneration effect not good.
1.Regenerate resin.
2.Replace resin.
3.Check if the drain pipeline blocked or
use the special regeneration salt.
Regeneration
effect not good
1.Do not use the special
regeneration salt.
2.The drain is blocked.
3.Source water is not opened
during regeneration.
1.Use the special regeneration salt.
2.Clean the drain line flow control.
3.Open the source water and
regenerate again.
E1 flash
1.Motor failure.
1.Replace motor.