background image

RUNLUCKY SHOWER SOFTENER 

 

 

 

2.3.3. Drain Pipeline Installation 

The product has been installed drain pipeline in the factory. If the drain pipeline is needed longer, as 

sewer is far away or other reason, please use 1/4 "quick connector to connect the drain pipeline. Be sure 
the flow control in drain pipeline placed as shown in Figure 22. Please contact your distributor if you lose 
it. 

 

2.3.4. Power Cable Installation 

The product needs the power supply far away from the water mist, when the machine is installed. The 

plug  of  power  cable  uses  the  seal  design.  When  installation,  please  tighten  the  connection  nut, 
installation as Figure 23. 

 

3.Trial Running 

 

1.Power on, slowly open the source water, let the machine run in service position for about five minutes 
to check if there is any leakage on connection. If leak, please tighten the leaking area. 
2.For the machine firstly use, there may be a little yellow water from the outlet ,this is a normal 
phenomenon. Because the resin is new, just rinse it. 

Note: Remove the plug on drain pipeline when uses the product to prevent no water drain out in 

Содержание RL-R50/MYA-1

Страница 1: ...mainly used for making soft water for shower can also be used in applications such as floor heating beauty salon hairdressing salon washing machines etc The treated water of the product can not be dru...

Страница 2: ...ater 4 2 3 2 Installed before Water Heater 5 2 3 3 Drain Pipeline Installation 8 2 3 4 Power Cable Installation 8 3 Trial Running 8 4 Regeneration Operation 9 4 1 Water Treatment Capacity 9 4 2 Regene...

Страница 3: ...y 5 The product is suit for municipal tap water water pressure is 0 1 0 6 MPa water temperature is 5 70 It is forbidden to use it out of the range 6 The product is only suitable for indoor installatio...

Страница 4: ...to maintain and replace the resin There is a check valve on outlet to prevent the water in water heater backflow Data saved after power off 1 2 Technical Parameters Item Requirement Working Pressure...

Страница 5: ...n and pipeline connection relate to installation type please refer the pipeline installation instruction in details When the resin goes invalid during the usage of the product it needs to add salt Dep...

Страница 6: ...xing valve with adjustable spanner as shown in Figure 4 2 3 1 2 Tighten the nut of sprinkler on the outlet of shower softener as shown in Figure 5 2 3 1 3 Connect the outlet of water mixing valve with...

Страница 7: ...ener as shown in Figure 8 and 9 2 3 2 Installed before Water Heater A Installation for electrical water heater solar water heater with double pipelines for water flowing up and down as well as some si...

Страница 8: ...schematic view of after water mixing valve installed According to the view and mark on connector adjust the outlet of cold water connector adown as shown in Figure 13 e In order to prevent the big gra...

Страница 9: ...f water mixing valve As the product doesn t have water flow out in regeneration process a spare outlet is reserved when distribute the pipelines if needs to use water These are common installation sch...

Страница 10: ...supply far away from the water mist when the machine is installed The plug of power cable uses the seal design When installation please tighten the connection nut installation as Figure 23 3 Trial Run...

Страница 11: ...with salt Operation methods 4 3 1 The shower softener needs water supplied for regeneration For the shower softener installed after water heater the ender user needs to open the water mixing valve to...

Страница 12: ...ross screwdriver b Take out the front cover of shower softener Be sure not scratch the surface c Unscrew 4 bolts which are used to fix resin tank to back cover by a cross screwdriver d Take out the re...

Страница 13: ...RUNLUCKY SHOWER SOFTENER 11 2 If the riser pipe falls out it needs to be cleaned and inserted into resin tank 3 Be sure the drain line flow control is undamaged when installing the drain pipeline...

Страница 14: ...and after water heater It has difference processes accordingly Resin invalid warning has time clock type and meter type Currently it only has time clock type The meter type will be developed later Th...

Страница 15: ...e Code Meaning Explaination Code Meaning Explaination Service Service Days Fast Rinse Water flows out from drain Backwash Water flows out from drain Salt Disslution Salt Disslution Fast Rinse Water fl...

Страница 16: ...It couldn t be retrieved if lost It couldn t be repaired free of charge under the below conditions 1 Guarantee period expired One year 2 Damage resulting from using maintenance and keeping that are n...

Отзывы: