![Runco Reflection RS-440 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/runco/reflection-rs-440/reflection-rs-440_user-manual_1500050075.webp)
Runco RS-440 Installation/Operation Manual
61
6.1
RS-232 Connection
and Port Configuration
To interface the RS-440 with a home theater automation/control system or a PC running
terminal emulation software, connect it to your control system or PC as shown in Figure
3-13.
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to 9600, to match that of the RS-440 RS-232
port.
6.2
Serial Command
Syntax
Table 6-1 lists the RS-232 command set. All commands are in ASCII format and must be
in UPPERCASE.
When you send a valid command, the RS-440 executes it and acknowledges it with the
first three characters of the command followed by “OK;” for example, “
RRAOK
.“ When you
send an invalid command, the RS-440 ignores it and returns the first three characters of
the command followed by “NG;” for example, “
RRXNG
.“
6.
S
erial Communication
s
Table 6-1.
S
erial Command
s
Command
De
s
cription
Reply
RRA00
Saves current settings to the CUSTOM memory
(Note 1)
RRAOK
RRA01
Saves current settings to the ISF Day memory
(Note 1)
RRAOK
RRA02
Saves current settings to the ISF Night memory
(Note 1)
RRAOK
RRB00
Recalls the Custom memory settings
RRBOK
RRB01
Recalls the ISF Day memory settings
RRBOK
RRB02
Recalls the ISF Night settings
RRBOK
RRC00
Selects the S-VIDEO input
RRCOK
RRC01
Selects the COMPOSITE VIDEO input
RRCOK
RRC02
Selects the COMPONENT input
RRCOK
RRC03
Selects the DVI-D input
RRCOK
RRC04
Selects the HDMI input
RRCOK
RRC05
Selects the DVI-A input
RRCOK
Notes:
1. All image quality settings must be made with the remote control. After the image adjustments
are complete, you can use these commands to store the settings in the selected memory.
2. The power on command (PON) will not provide an OK reply; it will instead reply with a random
character. For your automation system, simply ensure that you receive a character after the
PON command. If you do not get any reply after PON, send PON again.
Содержание Reflection RS-440
Страница 2: ......
Страница 12: ...Table of Contents xii Runco RS 440 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 14: ...List of Figures xiv Runco RS 440 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 50: ...Installation 36 Runco RS 440 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 68: ...Operation 54 Runco RS 440 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 74: ...Maintenance and Troubleshooting 60 Runco RS 440 Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 83: ......