![Runco LightStyle LS-12d Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/runco/lightstyle-ls-12d/lightstyle-ls-12d_installation-and-operation-manual_1500016133.webp)
External Control
LightStyle™ LS-12d Installation/Operation Manual
117
PRE
L
IMINAR
Y
6.2
Using Discrete IR
Codes
The Dimension Digital Controller accepts commands in the form of IR signals that conform
to the NEC protocol. Each Dimension Digital Controller remote control button has an NEC
control code associated with it.
You can use these codes to program a third-party, “universal” remote control unit to work
with the Dimension Digital Controller. These third-party products usually come with a
computer software application for this purpose. For more information, consult the
documentation provided with the remote control unit.
IR Command Protocol
The IR control codes have the following characteristics:
• Each code consists of the following:
• A
leader pul
s
e
(a modulated pulse of 9 ms followed by a non-modulated pulse of
4.5 ms);
• 16
addre
ss
bit
s
. The default address is
82 09
(0x2011, binary
00100000 00010001). To change it, select Remote Control from the Miscellaneous
menu (in the Service menu) and follow the steps given on page 83;
• 16
data bit
s
: eight (8) bits for the command followed by the logical inverse of the
command; and
• An
end pul
s
e
(a modulated pulse of 0.56 ms, similar to the modulated pulse in the
‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data
transmission.
• The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle.
• Commands are sent at a maximum rate of 9 Hz.
For example, here is the NEC control code for the
ON
button on the Dimension Digital
Controller remote control unit (assuming the default address is used):
Figure 6-1 shows the pulse train for this command.
Figure 6-1. NEC Protocol Me
ss
age Format
Hex
20
11
01
FE
Binary
00100000
00010001
00000001
11111110
Function
Addre
ss
Byte 1
Addre
ss
Byte 2
Command
Command
(Logical Inver
s
e)
9 ms
13.5 ms
27 ms
27 ms
Address Byte 1
Leader Pulse
Address Byte 2
Command Byte
Command Byte (logical inverse)
0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 1
0 0 0 0 0 0 0 1
1 1 1 1 1 1 1 0
4.5 ms
End Pulse
Содержание LightStyle LS-12d
Страница 1: ...LS 12d Active 3D Home Theater Projection System INSTALLATION OPERATION MANUAL ...
Страница 2: ......
Страница 14: ...Table of Contents xiv LightStyle LS 12d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 72: ...Installation 56 LightStyle LS 12d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 112: ...Operation 96 LightStyle LS 12d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 140: ...External Control 124 LightStyle LS 12d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 150: ...Specifications 134 LightStyle LS 12d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 151: ......
Страница 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1179 01 Rev A May 2012 ...