Install the PoE power system
The PoE power system and the DC power system share the same installation steps with the AC power system.
The total power of power supplies of the RG-S8600E must be greater than the working power of the host. Otherwise, some
modules may fail to start.
The host power is the summation of the power of all working modules, including the supervisor module, service module and fan.
For the power of each module, please refer to
RG-S8600E Series Switches Hardware Installation and Reference Guide.
4.9 Installing Fans
The RG-S8600E provides a ventilation system: M05-FAN for RG-S8605E, M07-FAN for RG-S8607E, M10-FAN-R, M10-FAN-F for
RG-S8610E and M12-FAN-R for RG-S8612E. Before the following procedures, wear an anti-static wrist trap close to your skin and
have it properly grounded.
Steps for installing the M05-FAN fan tray:
1)
Install the fan tray into the fan slot in the rear panel of RG-S8605E
. Note the direction identifier of the fan tray’s name to ensure
the correct direction.
2)
Tighten the captive screws on the fan tray with a screwdriver.
Figure 4-27 Installing M05-FAN Fan Tray