Direct or indirect touch through a wet object on high-voltage and commercial electricity may bring a fatal
danger.
Static Discharge Damage Prevention
To prevent damage from static electricity, pay attention to the following:
Connect the device's circuit to the ground.
Clear up the dust.
Maintain the proper humidity.
Laser
Among the modules supported by the RG-S5750-S series, many are Class I laser products. Therefore, pay attention to
the following when using them:
When a fiber transceiver works, ensure that the port has been connected with an optical fiber or is covered with a dust
cap, to keep out dust and avoid burning your eyes.
Do not approach or stare into any optical port, as this may cause permanent damage to your eyes.
Installation Site Requirements
The RG-S5750-S series must be used indoors. To ensure its functioning and prolong its service life, the installation site
must meet the following requirements.
Ventilation Requirements
RG-S5750-S should be placed at least 10cm away from surrounding walls to effective ventilation and heat dissipation.
Cables should be bunched or put on the cable frame after being connected in order to prevent blocking the air intake.
Dust the device every three months to avoid blocking the ventilation openings.
Temperature and Humidity Requirements
The temperature and humidity in the room must be stable to ensure the device's proper functioning and prolong its
service life.
Continuous improper temperature and humidity will cause damage to the device.
High relative humidity will reduce the insulation of insulation materials and cause electric leakage. Sometimes it may
lead to changes in the mechanical characters of materials and rust metal components.
Low relative humidity will dry the insulation sheets and generate static electricity, which will damage the electric circuits
of the device.
High temperature will large affect the device's reliability, shorten its service life and accelerate its aging.
Содержание RG-S5750-S Series
Страница 1: ...RG S5750 S Series Switch Hardware Installation and Reference Guide V1 15...
Страница 27: ...The RG S5750 S series are not provided with a tool kit Please prepare tools on your own...
Страница 39: ...Symptom Possible Causes Solution The RPS power supply cable is in loose contact cable is in loose contact...