Страница 4: ...irement for interfaces in network constructions RG S5750 S Series Switches Table1 1 Model 10 100 1000Base T adaptive Ethernet port 1000Base X SFP port Console Port USB Port Extension Module Slot Redun...

Страница 5: ...voltage range 100 240 V AC Maximum voltage range 90 264 V AC Frequency 50 60 Hz Rated current 1 5 A HVDC input Voltage range 192 290 V DC Current range 0 5 0 24 A Max Power Consumption 58 W with exten...

Страница 6: ...ombo ports one Console port and one USB port The back panel provides AC power input ports RPS input ports and two extension module slots Figure 1 1 Appearance of the RG S5750 24GT 8SFP S Front Panel F...

Страница 7: ...ch power is supplied by the AC power input When the AC input is unavailable the switch power supply switches to the redundant power input seamlessly At present the redundant power supply interface can...

Страница 8: ...extension module is not correctly installed Extension module indicator M1 M2 Solid green The extension module is correctly installed Off The redundant power is not connected to a link Solid green The...

Страница 9: ...cal Specifications Table1 5 Model RG S5750 48GT 4SFP S Optical Module Type Ethernet 100 MB FE SFP LX MM1310 FE SFP LH15 SM1310 FE SFP LX20 SM1310 BIDI FE SFP LX20 SM1550 BIDI FE SFP LH40 SM1310 BIDI F...

Страница 10: ...les Temperature Working temperature 0 50 C Storage temperature 40 70 C Humidity Working humidity 10 90 RH Storage humidity 5 90 RH Fan Support fan speed adjustment and the fault warning function Tempe...

Страница 11: ...Diagram of the RG S5750 48GT 4SFP S Front Panel Note 1 Switch status indicator 2 Extension port 1 status indicator 3 Extension port 2 status indicator 4 RPS status indicator 5 Console port 6 10 100 10...

Страница 12: ...h power supply switches to the redundant power input seamlessly At present the redundant power supply interface can be used together with the RPS150 that are manufactured by Ruijie Networks Unless oth...

Страница 13: ...wer is connected and can supply power Solid yellow The redundant power is supplying power RPS status indicator RPS Solid red The redundant power is connected but cannot supply power Off T No link or p...

Страница 14: ...BIC ZX80 Mini GBIC ZX100 1000Base T Mini GBIC GT The supported module type may change at any time For the detailed change information consult the Ruijie Networks The Bi Directional BIDI optical module...

Страница 15: ...EMC GB9254 2008 Security Compliance GB4943 2011 Dimensions W x D x H 440 mm x 300 mm x 44 mm Weight 5 2 kg with extension modules and power modules 3 7 kg without extension modules or power modules R...

Страница 16: ...FP 8GT S Back Panel Note 1 Slot for the power module 1 2 Slot for the power module 2 3 Slot for the extension module 1 4 Slot for the extension module 2 5 Grounding pole Power Supply System The RG S57...

Страница 17: ...Cable 10 A power cable Dimensions 203 3 mm x 81 mm x 40 mm excluding connecting finger and handle 236 9 mm x 81 mm x 40 mm including connecting finger and handle Weight 0 6 kg Cooling System The RG S...

Страница 18: ...d yellow It indicates a yellow warning on the switch temperature Check in time the working environment of the switch Status indicator Status Solid red Indicates a fault on the switch For details refer...

Страница 19: ...ode and it can be used together with multiple types of optical transceiver modules of Ruijie Networks for different transmission distances When you use this module for the RG S5750 S series switches t...

Страница 20: ...lus ports The 1000Base X SFP port and the corresponding 10 100 1000Base T adaptive Ethernet port form a fiber copper combo port That is only one port in the fiber copper combo port is available at a p...

Страница 21: ...being hurt Before moving the device turn off all power supplies and dismantle all power modules Electricity Observe local regulations and specifications when performing electric operations Relevant o...

Страница 22: ...ite must meet the following requirements Ventilation Requirements RG S5750 S should be placed at least 10cm away from surrounding walls to effective ventilation and heat dissipation Cables should be b...

Страница 23: ...ts The following table shows the requirements for the dust content and granularity in the equipment room Table 2 2 Substance Concentration Limit particles m3 Dust particles diameter 0 5 m 3 5 106 Dust...

Страница 24: ...tem is the basis for the stable and reliable operation of the RG S5750 S series preventing lightning stroke and resisting interference Please carefully check the grounding conditions on the installati...

Страница 25: ...y but unnecessary for equipment EMC Grounding The grounding required for EMC design includes shielding grounding filter grounding noise and interference suppression and level reference All the above c...

Страница 26: ...adiated interference can interrupt any signal paths of the device it is difficult to shield the device from such interference The power supplying system should be effectively protected by an electrici...

Страница 27: ...The RG S5750 S series are not provided with a tool kit Please prepare tools on your own...

Страница 28: ...e sure that the requirements set forth in Chapter 2 have been met Installation Procedure Pre installation Tasks Ensure the following points before installation Whether sufficient airflow is available...

Страница 29: ...located far away from the large power radio launch pad radar launch pad and high frequency large current devices If necessary electromagnetic shielding should be adopted For example use interface cab...

Страница 30: ...oles in the mounting bracket with the mounting holes in the rack as shown in Figure 3 2 Use the supplied M6 screws and cage nuts to securely attach the mounting brackets to the rack as shown in Figure...

Страница 31: ...p 1 Attach the mounting brackets to the switch with the supplied screws as shown in Figure 3 4 Figure 3 4 Attaching the Mounting Brackets to the Switch for Wall Mounting Step 2 Use the expansion screw...

Страница 32: ...bottom of the switch as shown in Figure 3 6 Figure 3 6 Attaching the Rubber Feet to the Recessed Areas Step 2 Place the switch on the table as shown in Figure 3 7 Figure 3 7 Mounting the Switch on th...

Страница 33: ...that the ground line is connected Check that the cables and power input cables are correctly connected Check that all interface cables are laid out inside the equipment room In the case of external c...

Страница 34: ...port of the PC Step 2 Connect one end of the console cable RJ45 to the console port of the switch Setting Terminal Parameters Step 1 Start the PC and run the terminal simulation program on the PC suc...

Страница 35: ...oose the series port used currently in the column use when connecting Figure 4 3 After choosing the series port click OK to display the series port parameter setting page set the baud rate at 9600 dat...

Страница 36: ...ment of the switch The console cable is correctly connected the terminal can be a PC used for configuration is already started the parameters are already configured Checking after Power on Recommended...

Страница 37: ...ogin password Please contact Ruijie Networks Customer Service Department for technical support The status indicator is not on after the switch is started The power supply module does not supply power...

Страница 38: ...connected twisted pair cable is faulty The length of the cable exceeds 100 m The port has special configuration that has no common working mode with the connected switch Replace the twisted pair cabl...

Страница 39: ...Symptom Possible Causes Solution The RPS power supply cable is in loose contact cable is in loose contact...

Страница 40: ...which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for the Four Twisted Pairs of the 1000BASE T In addition to the a...

Страница 41: ...ical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Schematic...

Страница 42: ...ty dbm DDM Yes No Min Max Min Max FE SFP LX MM1310 1310 MMF1 LC 62 5 125 2km 22 14 30 14 Yes FE SFP LH 15 SM1310 1310 SMF2 LC 9 125 15km 15 8 28 8 Yes FE SFP LX 20 SM1310 BIDI 1310TX 155 0RX SMF LC 9...

Страница 43: ...1550TX 131 0RX SMF LC 9 125 40km 5 0 24 1 Yes Mini GBIC GT N A UTP STP RJ45 port Categ ory 5 or Supp er Categ ory 5 UTP or STP 100m N A No 1 MMF Multimode fiber 2 SMF Single mode fiber One on line op...

Страница 44: ...r cables Pairs of SFP BIDI Modules Rate Distance Matching Models 100M 20 km FE SFP LX20 SM1310 BIDI FE SFP LX20 SM1550 BIDI 100M 40 km FE SFP LH40 SM1310 BIDI FE SFP LH40 SM1550 BIDI 1000M 20 km GE SF...

Страница 45: ...m 26m XG SFP SR MM850 850 multi mode optical fiber LC connector 50 2000 500 400 300m 82m 66m 5 1 7 5 0 5 XG SFP LR SM1310 1310 single mode optical fiber LC connector 9 N A 10km 8 2 0 5 10 3 0 5 XG SFP...

Страница 46: ...M Passive SFP Plus 3 m 28 10 3125 No Note electrostatic discharge ESD prevention and protection while using the SFP Plus copper cable Please keep the beveling radius of the SFP Plus copper cable not l...

Страница 47: ...as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet t...