Hardware Manual
Chapter 2 Installation
2-3
Figure 2-2
Schematic Diagram for Fastening the Switch
Caution
Please ensure that the ventilation holes and fans on both sides and at the
back of the chassis are not blocked.
2.4
System Connection
2.4.1
Connecting the RJ-45 Port
Use shielded or unshielded twisted pair cables with RJ-45 connectors on both ends. Use
cables of Category 3, 4, and 5 to connect the 10Mbps Ethernet, and use cables of Category
5 to connect the 100/1000Mbps Ethernet ports. Connect one end of a cable to the network
card or the RJ-45 port of another switch/HUB, and the other end to the RJ-45 port of the
switch. When you plug the RJ-45 connector, you should hear a
“
click
”
, which means that the
connector is plugged tightly.
Warning
Do not insert a phone connector into the RJ-45 port, as this may damage the
switch.
Caution
Ensure that each twisted pair cable does not exceed 100 m in length.