background image

Chapter 1    Product Overview 

Hardware Manual 

1-16 

 

 

Item 

Status 

Description 

Solid orange 

POE power failure 

OFF 

The port is not connected. 

The port is not supplying power. 

S5750P-48GT/4

SFP  port  PED 

indicating 

the 

POE 

status 

defined to 

 Note 

Solid green 

The port is supplying power normally. 

Solid orange 

The power needed by the mounted device exceeds 

the  maximum capacity  of  the  port;  The  total  supply 

power  of  the  switch  has  reached  the  maximum 

capacity  of  the  switch.  Therefore,  this  port  cannot 

supply power. 

Solid red 

POE power failure 

Off 

The port is not connected. 

The port does not supply external power. 

Note  4:  The  1000M  SFP  port  of  the  S5750-48GT/4SFP  and  S5750S-48GT/4SFP  also 

provide the module presence indicator. When a SFP module is inserted in the SFP port, the 

corresponding LED turns on, indicating that the module is recognized.   

Note  5/6:  The  port  LED  indicating  the  POE  status  is  a  feature  specific  to  the 

S5750P-24GT/12SFP  product.  The  port  LEDs  of  other  products  do  not  feature  POE 

indication. 

Table 1-7 

  Identifications on the Backplane 

Identification 

Description 

Detailed Information 

Xe1   

10G extended 

port 1 

10G extended port of the switch, to be used with our 

5700-01XFP, 

M5700-01XENPAK 

and 

M5700-STACK conversion boards for providing  the 

switch with 10G port or stack port. 

Xe2   

10G extended 

port 2 

10G extended port of the switch, same as Xe1   

220VAC   

220V AC 

power port 

Providing a 220V supply port on the left of the rear 

panel of the chassis   

RPS-12V   

Redundancy 

power port (not 

supported by 

the S5750P) 

The  port  for  the  redundancy  power  supply  of  the 

switch,  through  which  the  external  DC  redundancy 

power supply can be used to power the switch when 

the built-in power supply fails   

RPS 

Redundancy 

power 

port 

(supported  by 

only 

the 

The  redundancy  power  supply  mode  of  the  switch, 

through  which  the  external  DC  redundancy  power 

supply  can  be  used  to  power  the  switch  when  the 

built-in  power  supply  fails.  The  RPS500-A  can 

Содержание M5750-24GT/12SFP

Страница 1: ...Security Intelligent 10G Multi layer Switch S5750 Series Installation Manual...

Страница 2: ...y means are all registered trademarks of Ruijie Networks Co Ltd and are protected by law Disclaimer The information contained in this manual may be modified without notification Ruijie Networks has tr...

Страница 3: ...escription and modified the product technical specifications Li Lingpeng 2009 03 23 1 31 1 31 Modified the dimensions of the S5750 series cabinets that is product technical specifications Li Lingpeng...

Страница 4: ...e scope of application main features technical specifications and related extension modules of the product n Chapter 2 Preparation Before Installation lists the safety power supply and site requiremen...

Страница 5: ...solution and software upgrading information n Customer service center of Ruijie Networks which can provide all customers with needed technical assistance for Products technologies and solutions The cu...

Страница 6: ......

Страница 7: ...ion 2 1 2 1 Prior Preparation 2 1 2 2 Desktop Mounting 2 1 2 3 Rack Mounting 2 2 2 4 System Connection 2 3 2 4 1 Connecting the RJ 45 Port 2 3 2 4 2 Connecting Optical Fibers 2 4 2 4 3 Laser Safety 2...

Страница 8: ......

Страница 9: ...ing and network attacks prevent illegal users from accessing the network and ensure that legal users can reasonably use network resources This guarantees the safe and reasonable use and operation of t...

Страница 10: ...dwidth provides non blocking feature to all ports n Abundant and perfect routing capability as well as super large routing table can satisfy dynamic routing of large scale networks n The routing forwa...

Страница 11: ...on can effectively prevent illegal multicast source and improve the network security n Support IGMPv1 v2 v3 all versions adapt to different multi cast environment and satisfy the necessity of multi ca...

Страница 12: ...or to maintain and manage n Synchronous monitoring of multiple ports makes it possible to monitor the data flows incoming frames outgoing frames or both on multiple ports just through one of them grea...

Страница 13: ...pps L3 wire speed 66 Mpps 802 3af POE standard Only for S5750P 802 1q VLAN 4 K ACL Standard IP ACL IP address based hardware ACL Extended IP ACL IP address based and TCP UDP port number based hardware...

Страница 14: ...rts are connected with PD for the S5750P 460 W Temperature Operating temperature 0 C 45 C Storage temperature 40 C 70 C Humidity Operating humidity 10 90 RH Storage humidity 5 90 RH Table 1 2 Technica...

Страница 15: ...e speed 66 Mpps 802 1q VLAN 4 K ACL Standard IP ACL IP address based hardware ACL Extended IP ACL IP address based and TCP UDP port number based hardware ACL MAC extended ACL source MAC address based...

Страница 16: ...xing SFP ports 2 10G expantion slots Available module Mini GBIC SX single port 1000BASE SX mini GBIC conversion module LC interface Mini GBIC LX single port 1000BASE LX mini GBIC conversion module LC...

Страница 17: ...ACL based on the flexible combinations of VLAN number Ethernet type MAC address IP address TCP UDP port number protocol type and time L2 Protocol IEEE802 3 IEEE802 3u IEEE802 3z IEEE802 3x IEEE802 3a...

Страница 18: ...ASE ZX mini GBIC conversion module LC port 80 km M5700 01XENPAK 1 port XENPAK 10G conversion board M5700 01XFP 1 port XFP 10G conversion board M5700 STACKL Single port 10G stack module 10G fiber inter...

Страница 19: ...EEE802 1d IEEE802 1w IEEE802 1s IGMP Snooping v1 v2 v3 LLDP Defeat DoS Attack Supported Defeat IP Scan Supported L3 protocol OSPF ECMP WCMP RIPv1 v2 PIM DM SM SSM DVMRP VRRP IGMPv1 v2 v3 Management pr...

Страница 20: ...perature Working temperature 0 C to 45 C Storage temperature 40 C to 70 C Humidity Working humidity 10 to 90 RH Storage humidity 5 to 90 RH 1 3 Product Appearance Figure 1 1 Appearance of the RG S5750...

Страница 21: ...of the RG S5750P 48GT 4SFP Table 1 5 LEDs on the Front Panel Identification Applicable Model Description Detailed Information status l S5750S Note 1 l S5750 Note 2 l S5750P 24 l S5750 24SFP 12GT Syste...

Страница 22: ...port LED indication mode This button controls the port LED to show the switching status or the POE power status MOD LED S5750S S5750 l S5750P 24 S5750 24SFP 12GT l S5750P 48 Port mode LED This LED is...

Страница 23: ...have the named function and has no corresponding LED Note 1 The S5750S includes both the S5750S 24GT 12SFP and S5750S 48GT 4SFP Note 2 The S5750 includes both the S5750S 24GT 12SFP and S5750 48GT 4SFP...

Страница 24: ...cating the POE status is a feature specific to the S5750P 24GT 12SFP product The port LEDs of other products do not feature POE indication Table 1 7 Identifications on the Backplane Identification Des...

Страница 25: ...e S5750 which supports up to M5700 01XENPAK conversion boards The M5700 01XFP conversion board does not support hot plugging unplugging so please install or remove it after the switch is powered off n...

Страница 26: ...ceives the power that is the client device of the POE system for example IP phone network safety camera AP and PDA or mobile phone charger Our RG S5750P 24GT 12SFP and RG S5750P 48GT 4SFP switches sup...

Страница 27: ...Hardware Manual Chapter 1 Product Overview 1 19 so that the MOD LED turns green the port LED of the switch returns to indicate the switching status...

Страница 28: ......

Страница 29: ...entering the switch Keep the switch away from the places with much dust or strong electromagnetic interference 2 2 Desktop Mounting Step 1 Attach the four adhesive rubber pads provided in the carton o...

Страница 30: ...doing this you can use the attached two L shaped handle fastening brackets and 6 M3 10FMO sunk screws Step 1 Keep the fastening brackets with handles closely onto both sides of the switch align with t...

Страница 31: ...ds Use cables of Category 3 4 and 5 to connect the 10Mbps Ethernet and use cables of Category 5 to connect the 100 1000Mbps Ethernet ports Connect one end of a cable to the network card or the RJ 45 p...

Страница 32: ...vered with dust plugs as dust may pollute or damage the laser connectors Danger Never stare into the optical module Tx ends and the connected fiber jumpers to avoid injuries to your eyes 2 5 Connectin...

Страница 33: ...ia the CLI you must first connect the Console port of the switch to the computer The cables needed for such connection are provided with the switch The computer must be installed with a particular typ...

Страница 34: ......

Страница 35: ...rt is not configured correctly Change the serial port opened by the configuration software to be the one connected to the switch Verify that the parameter configuration of the serial port matches that...

Страница 36: ...The RPS power supply used is not the specified model The RPS power supply fails The RPS power cable is in loose contact Use the RPS power supply specified by Ruijie Replace the RPS power supply Check...

Страница 37: ...P or STP which can be up to 100 m The 1000BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BAS...

Страница 38: ...Figure A 3 Connections of the Twisted Pairs of the 100BASE TX 10BASE T Straight Through Crossover A 2 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical f...

Отзывы: