23
2007 RuggedCom Inc. All rights reserved
Rev100
5.5 Ethernet Ports
5.5.1 Copper Ports
Parameter
Specification
Notes
Speed
10/100 Mbps
Auto-negotiating
Duplex
FDX / HDX
Auto-negotiating
Cable-Type
> Category 5
Shielded/Unshielded
Wiring Standard
TIA/EIA T568A/B
Auto-Crossover, Auto-polarity
Max Distance
100 m
Connector
RJ45
Isolation
1.5 kV
RMS 1-minute
Table 9: Ethernet Ports - Copper Specifications
5.5.2 Fiber Optic Ports
Speed
Standard
Mode /
Connector
Tx
λ
λ
λ
λ
(nm)
Cable
Type
2
(
µ
µ
µ
µ
m)
Tx Pwr
(dBm peak)
3
(Min / Max)
Rx
Sensitivity
(dBm Average)
3
Rx Saturation
(dBm Peak)
3
Typical
Distance
(km)
1
Power
Budget
(dB)
100Base-FX
MM / ST
1310
50/125
-15.7
-33.5
-11
2
17
100Base-FX
MM / SC
1310
50/125
-16/-11
-33
-11
2
17
100Base-FX
MM / LC
1310
50/125
-19 / -14
-32
-14
2
15
100Base-FX
MM / MTRJ
1310
50/125
-16/-11
-33.5
-11
2
17
100Base-FX
SM / ST
1310
9/125
-15/-8
-32
-7
20
16.5
100Base-FX
SM / SC
1310
9/125
-13/5
-31
-4
20
20
100Base-FX
SM / LC
1310
9/125
-15/-8
-31
-5
15
16.5
Table 10: Ethernet Ports – Fiber Optic Specifications
NOTES:
1.
Maximum segment length is dependent on factors such as fiber quality, and number of patches and splices.
Please consult RuggedCom sales associates when determining maximum segment distances.
2.
To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
5.6 Communication Standards
Protocol
Standards
Ethernet
IEEE 802.3
Table 11 - Communication Standard Compliance