RS900 Family Installation Guide
Page 42 of 42
©
2008 RuggedCom Inc. All rights reserved.
Rev100
7.2 IEEE 1613 Type Tests
IEEE Test IEEE 1613
Clause
Description
Test Levels
Enclosure Contact
+/- 8kV
C37.90.3 9
ESD
Enclosure Air
+/- 15kV
C37.90.2
8
Radiated RFI
Enclosure ports
35 V/m
Signal ports
+/- 4kV @ 2.5kHz
D.C. Power ports
+/- 4kV
A.C. Power ports
+/- 4kV
C37.90.1 7 Fast
Transient
Earth ground ports
+/- 4kV
Signal ports
2.5kV common mode @ 1MHz
D.C. Power ports
2.5kV common & differential mode @ 1MHz
C37.90.1 7
Oscillatory
A.C. Power ports
2.5kV common & differential mode @ 1MHz
Signal ports
5 kV (Failsafe Relay)
D.C. Power ports
5 kV
C37.90 6 H.V.
Impulse
A.C. Power ports
5 kV
Signal ports
2kV AC(Failsafe Relay)
D.C. Power ports
2kV AC
C37.90 6 Dielectric
Strength
A.C. Power ports
2kV AC
Table 26 - IEEE 1613 Type Tests
NOTE:
•
If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur
but recovery is automatic).
•
If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will
occur).
7.3 IEC Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 deg. C, 16 Hours
N/A
IEC 60068-2-2
Dry Heat
Test Bd
+85 deg. C, 16 Hours
N/A
IEC 60068-2-30
Humidity (Damp Heat,
Cyclic)
Test Db
95% (non-condensing), 55°C, 6 cycles
N/A
IEC 60255-21-1
Vibration
Tests Fc
2g @ (10-150) Hz
Class 2
IEC 60255-21-2
Shock
Tests Ea
30g @ 11 ms
Class 2
Table 27 - Environmental Type Tests