background image

 

 

Copyright 

This document contains proprietary information, which is protected by copyright. No part of this document may be 

photocopied, reproduced or translated to another language without the prior written consent of RuggedCom Inc. 
 

Disclaimer 

RuggedCom has checked the contents of this manual against the hardware and software described. However, 

deviations from the description cannot be completely ruled out. RuggedCom shall not be liable for any errors or 
omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this 

material. The information given in this document is reviewed regularly and any corrections will be included in 

subsequent editions. RuggedCom reserves the right to revise this document or withdraw it at any time without prior 

notice. 

 

FCC Radio Frequency Interference Statement 

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to 

radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his expense.  
 

Caution 

This product contains a laser system and is classified as a “CLASS 1 LASER PRODUCT”. Use of controls or 

adjustments or performance of procedures other than those specified herein may result in hazardous radiation 
exposure.  

 

Important 

This product contains no user serviceable parts. Attempted service by unauthorized personnel shall render all 
warranties null and void. 

 

This unit should be installed in a restricted access location where access can only be gained by service personnel or 

users who have been instructed about the reasons for the restrictions applied to the location and about any 
precautions that shall be taken; and access is through the use of a tool or lock and key, or other means of security, and 

is controlled by the authority responsible for the location.

 

 

 

Trademarks 
Ethernet is a trademark of Xerox Corporation 

RuggedSwitch, RuggedRated, ROS and eRSTP are trademarks of RuggedCom® Inc. 

 

Warranty 

RuggedCom warrants to Purchaser that Products are free from defects in material and workmanship for five (5) years 
after shipment. For warranty details, visit http://www.ruggedcom.com or contact your customer service representative.  

 

Contacting RuggedCom 

 
Corporate Headquarters 

30 Whitmore Road,  

Woodbridge, Ontario, L4L 7Z4 

Canada 
 

Toll Free: (888) 264-0006 

Tel:          (905) 856-5288  

Fax:         (905) 856-1995 

US Corporate Headquarters  

 1930 Harrison St. Suite-307 

Hollywood, Florida, 33020 

USA 
 

Toll Free: (866) 922-7975 

Tel:          (954) 922-7975 

Fax:         (954) 922-7984 

European Headquarters 

Unit 41, Aztec Centre 

Aztec West, Almondsbury, Bristol 

BS32 4TD, United Kingdom 
 

Tel:  +44 1454 203 404 

Fax: +44 1454 203 403 

 

Technical Support: 

North America: (954) 922-7975 | North America (Toll Free): (866) 922-7975 | International: +1 (905) 856-5288 

Email: 

[email protected]

 

Содержание RUGGED VDSL RS910L

Страница 1: ...RS900 Series Family of Switches Installation Guide www ruggedcom com...

Страница 2: ...n This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardou...

Страница 3: ...RJ11 Ethernet over VDSL Port 21 3 2 RJ45 Ethernet Port 25 3 3 Fiber Optic Ethernet Port 26 3 4 Wireless Ethernet Port 27 4 Serial Ports 28 4 1 DB9 Serial Port 28 4 2 RJ45 Serial Port 29 4 3 Fiber Ser...

Страница 4: ...RS900 Family Installation Guide 7 2 IEEE 1613 Type Tests 42 7 3 IEC Environmental Type Tests 42 Page 4 of 42 2008 RuggedCom Inc All rights reserved Rev100...

Страница 5: ...Female DCE pin out 20 Table 3 RJ11 port pin out 22 Table 4 RJ11 port LED description 22 Table 5 Typical Performance on 24 AWG PIC twisted pair with Universal EoVDSL ports 23 Table 6 Typical Performanc...

Страница 6: ...s for mission critical real time control applications RS900 Family Common Product Features Operating temperature 40 to 85 C no fans Fully integrated power supply Power supply options 12 24 48 or 60 VD...

Страница 7: ...S900 Family Installation Guide 1 2 RuggedSwitch RS900 9 Port Fiber Optic Ethernet Switch Up to 9 fast Ethernet ports Copper and fiber options Page 7 of 42 2008 RuggedCom Inc All rights reserved Rev100...

Страница 8: ...EE 802 1X RADIUS using EAP PEAP for secure enterprise class authentication configuration Pre shared Key Mode PSK for personal mode authentication configuration RS900W Wireless Ethernet with integrated...

Страница 9: ...RS422 RS232 Serial ports DB9 or RJ45 Serial Fiber interface ST available Power Alarm Port 7 Ethernet over VDSL Ports 1 2 Serial Port 9 Antenna 1 Port 9 Antenna 2 RS930W Wireless Ethernet with Integrat...

Страница 10: ...l speed configuration available RS900L Ethernet over VDSL with integrated 8 Port Switch 1 EoVDSL interface Up to 8 fast Ethernet ports Copper and fiber options RS910L Ethernet over VDSL with 2 Serial...

Страница 11: ...RS485 RS422 RS232 Serial ports DB9 or RJ45 Serial Fiber interface ST available Port 3 Ethernet over VDSL Ports 1 2 Serial Power Alarm Port 9 Ethernet over VDSL RS930L Dual Ethernet over VDSL interfac...

Страница 12: ...10 2 Port Serial Device Server with up to 3 Ethernet Ports 2 RS485 RS422 RS232 Serial ports DB9 or RJ45 Serial Fiber interface ST available Up to 3 fast Ethernet ports Copper and fiber options Page 12...

Страница 13: ...s 3 4 10 100Base TX or 100Base FX Ports 1 6 10 100Base TX Power Alarm Reset Figure 1 Front Panel Description Status LED Colour Activity Comments Power LED Green Solid Power On Alarm LED Red Solid Alar...

Страница 14: ...ion Guide 1 7 Bottom Panel Description Failsafe Relay Console Port Power Port Chassis Ground Optional Din Rail Mounting Bracket Figure 2 Bottom Panel Description Page 14 of 42 2008 RuggedCom Inc All r...

Страница 15: ...2 1 Din Rail Mounting An optional DIN rail mounting bracket is available for the unit The figure below details mounting instructions for the standard 1 DIN Rail Figure 3 DIN Rail Mounting Page 15 of 4...

Страница 16: ...iate grounding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Chassis Ground must be connected to the AC ground terminal NOT...

Страница 17: ...nd should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry inte...

Страница 18: ...is provided to signal critical error conditions that may occur on the unit The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs Figu...

Страница 19: ...HIPOT testing done in the field must have the braided ground cable disconnected during the test This is required in order to prevent the surge suppression circuitry which is connected to surge ground...

Страница 20: ...from the PC side since this has been done internally Figure 8 RS232 Female DCE pin out Pin Signal 1 No Connection 2 Transmit Data 3 Receive Data 4 No Connection 5 Ground 6 No Connection 7 No Connectio...

Страница 21: ...ach EoVDSL Universal EoVDSL ports are Master Slave selectable and offer symmetric data rates up to 35 Mbps with distances up to 2 5 km Long Reach EoVDSL ports are fixed as either Master or Slave but o...

Страница 22: ...Established Link Act Green Blinking Tx Activity Table 4 RJ11 port LED description 3 1 4 Configuration Setup If the units have Universal EoVDSL ports use the software to configure one unit as a Master...

Страница 23: ...ge AWG Polyethylene Insulated Cable PIC twisted pair the following performance is typical with Universal EoVDSL ports Distance km Distance feet Downstream Upstream Mbps Time to Achieve Port Up in Auto...

Страница 24: ...ons and are not to be connected to the Public Switched Telephone Network PSTN 2 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord 3 In Manual Mode assuming the distan...

Страница 25: ...shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end The figure below shows the shows the RJ45 port pin out and LEDs Figure 10 RJ45 port pin out and LE...

Страница 26: ...ort must be properly connected and matched for proper link and operation The drawings in the following figures show each fiber optical connector style with a side and top view to allow the user to ide...

Страница 27: ...technologies as well as answers to frequently asked questions Refer to the Rugged Operating System ROS User Guide for instructions on wireless port configuration Both of the above documents can be do...

Страница 28: ...TS 9 RI No Connection Shield Chassis Ground Table 9 DB9 Female DCE Port pin out NOTES 1 No internal termination is provided 2 Pins 1 4 and 6 are connected internally Pins 7 and 8 are connected interna...

Страница 29: ...45 Port pin out NOTES 1 No internal termination is provided 2 Pins 1 2 and 3 are connected internally Pins 7 and 8 are connected internally The pins are permanently asserted to 5V so that DTE devices...

Страница 30: ...ows RS485 RS422 or RS232 devices to communicate over secure noise immune optically isolated fiber optic cabling at extended distances as well as protocol independent conversion to multimode fiber opti...

Страница 31: ...ommended 2 The correct polarity must be observed throughout a single daisy chain 3 The number of devices wired should not exceed 32 and total distance should be less than 4000 feet at 100 kbps 4 The C...

Страница 32: ...m electrical transients and to ensure IEC 61850 3 and IEEE 1613 Class 1 conformance This means that during the transient event communications errors or interruptions may occur but recovery is automati...

Страница 33: ...5 T 1 5 kV DC 24 VDC 18 VDC 36 VDC 3 15 T 1 5 kV DC 48 VDC 36 VDC 72 VDC 3 15 T 1 5 kV DC HI 125 250 VDC 1 HI 110 230 VAC 1 88 VDC 85 VAC 300 VDC 265 VAC 3 15 T 4 kV AC 5 5 kV DC 10W Table 12 Power Su...

Страница 34: ...11 Ethernet over VDSL Port Specifications Data Port Media Distance Connector Type EoVDSL CAT 3 UTP or STP 2500m RJ11 Table 15 RJ11 Ethernet over VDSL Port Specifications 6 4 2 RJ45 Ethernet Port Speci...

Страница 35: ...100FX SM ST 1310 9 125 15 7 34 3 20 19 L2 100FX SM LC 1300 9 125 15 8 38 3 20 23 C2 100FX SM SC 1300 9 125 15 8 31 7 20 16 L5 100FX SM LC 1310 9 125 5 0 35 3 50 30 C5 100FX SM SC 1310 9 125 5 0 34 3...

Страница 36: ...e 6 4 4 Communication Standards Protocol Standards Ethernet IEEE 802 3 VDSL ETSI TS 101 270 2 V1 1 1 ITU T G 993 1 ANSI T1E1 4 Table 18 Communication Standard Compliance Page 36 of 42 2008 RuggedCom I...

Страница 37: ...rds Supported 6 5 2 Radio Characteristics Standard Parameter Modulation Direct Sequence Spread Spectrum 802 11b OFDM 802 11g Frequency Range 2 4 Ghz 2 4965 Ghz Data Rate 6 54 Mbps OFDM 11 Mbps CCK 5 5...

Страница 38: ...6 2437 X X X X 7 2442 X X X X 8 2447 X X X X 9 2452 X X X X 10 2457 X X X X 11 2462 X X X X 12 2467 X X X 13 2472 X X X 14 2484 X Table 21 Channel allocations for IEEE 802 11b g NOTES Mexico is inclu...

Страница 39: ...onnector DB9 or RJ45 Isolation 2 5 kV RMS 1 minute Table 22 Copper Port Specification 6 6 2 Fiber Serial Port Specifications Parameter Specifications Mode Multimode Connector ST Typical Dist km 5 Opti...

Страница 40: ...s Parameter Value Dimensions 16 8 x 11 7 x 6 6 cm 6 6 x 4 6 x 2 6 inches Weight 1 2 kg 2 7 lbs Enclosure 20 AWG Galvanized Steel Table 24 Mechanical Specifications Figure 19 Mechanical Specifications...

Страница 41: ...D C Power ports 30 for 0 1s 60 for 0 1s 100 for 0 05s N A IEC 61000 4 29 30 for 1 period 60 for 50 periods N A IEC 61000 4 11 Voltage Dips Interrupts A C Power ports 100 for 5 periods 100 for 50 peri...

Страница 42: ...C Power ports 5 kV Signal ports 2kV AC Failsafe Relay D C Power ports 2kV AC C37 90 6 Dielectric Strength A C Power ports 2kV AC Table 26 IEEE 1613 Type Tests NOTE If the unit contains copper ports th...

Отзывы: