RUGGEDCOM RSG2488
User Guide
Chapter 3
Device Management
Deleting an RMON History Control
81
Parameter
Description
The maximum number of buckets requested for this RMON collection history group of
statistics. The range is 1 to 4000. The default is 50.
Granted Buckets
Synopsis:
0 to 65535
The number of buckets granted for this RMON collection history. This field is not
editable.
Interval
Synopsis:
1 to 3600
Default:
1800
The number of seconds in over which the data is sampled for each bucket. The range is
1 to 3600. The default is 1800.
Owner
Synopsis:
Any 127 characters
Default:
Monitor
The owner of this record. It is suggested to start this string withword 'monitor'.
4. Click
Apply
.
Section 3.11.1.3
Deleting an RMON History Control
To delete an RMON history control, do the following:
1. Navigate to
Ethernet Stats > Configure RMON History Controls
. The
RMON History Controls
table appears.
Figure 47: RMON History Controls Table
2. Select the history control from the table. The
RMON History Controls
form appears.