Section 2 

– 

Installation

Read this manual before installing the CardioWall FreeStyle units. 

Installation Guidelines: 

▪ Complete a 

Site Survey 

form prior to delivery and/or installation.

▪ Send a completed 

Installation Checklist 

after any installation back to Rugged Interactive.

▪ A typical installation should take 2 people about 2 hrs.
▪ The wall surface must be flat over the area of the wall: 1220 mm wide x 1260 mm tall per

CardioWall.

▪ A suitable electricity supply should be available within 1000 mm (110 - 230V 13A).
▪ Avoid trapped and/or pinched cables.
▪ Use good practice when running data cables to and from products, external pods and sensors.

Support long cables at least every 50 cm and provide adequate strain relief for connection points.

▪ To prevent electric shock, keep all electric components away from contact with water.
▪ IMPORTANT: Take anti-static precautions.

Structure: 

▪ The units must be mounted to a construction capable of supporting its weight and gameplay.
▪ Typical suitable construction would be block built, portal frame with structural infills or brick built.
▪ Alternatively, mount onto 18 mm plywood (12 mm minimum) mechanically mounted to a steel

framework (50 mm box minimum). The steel uprights behind the plywood must be at least 100 mm
from the vertical centre line of each unit to avoid the clashing with the centre fixing holes. The
plywood should be covered with foam-backed vinyl.

▪ Units can either be secured on top of the foam-backed vinyl or embedded in a purpose-made cut- 

out. Adequate holes will need to be cut during installation to provide clearance for cable access to
rear if required.

▪ Do not fix to plasterboard faced partition. Avoid stud walls or unsupported portal infills.
▪ It is firmly recommended that the units are installed onto a wall that projects forward at least 0.3 m

over the edge of the trampoline. This ensures that users land in the middle of  the trampoline bed.

Fixings: 

▪ The manufacturer will supply fixings.
▪ Use hex-headed screws of 50-70 mm length (2”) x M10 for a plywood structure.
▪ Use Rawl Plugs (plastic wall plugs) if mounted to a solid block or brick wall.
▪ 10 x 35 ‘penny’ washers to spread the load at each bolt head are recommended.
▪ All fixings must be tight and secure.

Содержание CardioWall FreeStyle

Страница 1: ...Installation and Instruction Manual For models from May 2018 onwards Rugged Interactive Unit 1 Callywith Court Callywith Industrial Estate Bodmin Cornwall UK PL31 2RQ 44 0 1726 981 123 www rugged int...

Страница 2: ...active co uk hello rugged interactive co uk Rugged Interactive 2019 Contents Section 1 Safety Guidelines Section 2 Installation Section 3 Pod Removal and Installation Section 4 How to Use Section 5 Pr...

Страница 3: ...gameplay If possible avoid stud walls or unsupported portal infills If in doubt always contact a suitably qualified surveyor to check Visually check the product for any signs of damage component fail...

Страница 4: ...ts prior to participation Long hair should be tied back Before use loosen up with warm up exercises and stretches Practice being in control of your bounce before using the equipment Be aware of how to...

Страница 5: ...extreme moves unless you know you are capable and have had the appropriate training No double flips triple flips diving or gainers even if you are capable Do not distract others while they are using t...

Страница 6: ...on capable of supporting its weight and gameplay Typical suitable construction would be block built portal frame with structural infills or brick built Alternatively mount onto 18 mm plywood 12 mm min...

Страница 7: ...cloth and gentle cleaning spray Installation Heights The CardioWall FreeStyle Duo units can be installed either at the same height as each other or offset at different heights to accommodate both tall...

Страница 8: ...ons A waiting spectating area positioned nearby is advised A leaderboard to go with each unit is highly recommended IF YOU ARE IN ANY DOUBT CALL RUGGED INTERACTIVE DIRECTLY ON 44 0 1726 833 882 Figure...

Страница 9: ...ll FreeStyle Installation 2 people required one to hold the main body in place one to ensure it is level See Installation Heights Section 1 01 2 people required one to hold the main body in place one...

Страница 10: ...ction 2 Installation Section 2 4 CardioWall FreeStyle Installation cont 04 05 Position appropriate fixings by hand in all corners and tighten with a tool x 4 checking level Position fixing covers and...

Страница 11: ...5 connections Fix MPL using any suitable self tapping or wood screws into the surface material The MPL can be recessed to be flush with the surface or affixed on top of the foam backed vinyl if necess...

Страница 12: ...ioWall FreeStyle Installation and Instruction Manual Section 2 Installation CAT5 Cable Connections Notes The units can be arranged in any position The MPL power cable PWR can be connected to either un...

Страница 13: ...Removing the Pods 3 2 Installing the Pods Read this manual before removing or installing any pods One pod will be secured behind one section of the CardioWall Do not worry which order the pods come o...

Страница 14: ...umber for the CardioWall The CardioWall FreeStyle has two programs 1 ClearOut Speed 1 minute 2 Chaser Reaction 1 minute The green pods shown in Figure 4 1 are QuickStart options for the single player...

Страница 15: ...l appear green On selection of each illuminated pod the light will turn out Once all lit pods are cleared all pods will reappear blue Once all of the blue pods are cleared all pods will reappear red O...

Страница 16: ...eral vision Gameplay A single red pod will illuminate at random On selection of the red pod the chaser another pod will reappear red Aim To hit as many red pods with in the given time limit as possibl...

Страница 17: ...ooting Flow Diagram for diagnostic and repair instructions for the CardioWall FreeStyle Please make sure to read all of the options first Refer to Figures 6 2 and 6 3 for support if necessary Before b...

Страница 18: ...CardioWall FreeStyle Installation and Instruction Manual Section 6 Troubleshooting Guide Section 6 2 Rugged Interactive 2019...

Страница 19: ...l Troubleshooting Flow Diagram Figure 6 2 HUB Diagram Figure 6 3 CardioWall FreeStyle Pod Numbers and Corresponding CAT5 Cable Colours Power cable connection to PCB Volume dial Speaker connection to P...

Страница 20: ...egulatory Requirements CE Approved Operating Environment Indoors keep dry and out of direct sunlight Mount to a wall of a suitable construction Area required clear in front of the CardioWall depth of...

Страница 21: ...oWall FreeStyle Installation and Instruction Manual CardioWall FreeStyle System Specifications Rugged Interactive 2019 Figure 1 CardioWall FreeStyle mounting points Dimensions in mm 1185 R40 1000 1000...

Страница 22: ...cables No loose cables that could become a tripping hazard All long cables are supported at least every 50 cm Adequate strain relief provided for connection points Kept out of direct sunlight during t...

Страница 23: ...eady for use Play area is clear Instruction training carried out by an appropriate instructor to all new users If anything unexpected occurs or problems persist after troubleshooting call Rugged Inter...

Отзывы: