Section 2
-
3
©
Rugged Interactive
2019
CardioWall FreeStyle Installation and Instruction Manual:
Section 2
–
Installation
Required Tools and Consumables:
▪ A spirit level – to check floor is level before installation and that the CardioWall is level during
installation.
▪ An industrial vacuum cleaner.
▪ A dustpan and brush.
▪ A SDS impact drill.
▪ A cordless drill – with torque adjuster to avoid over-tightening of screws.
▪ A set of No.2 pozi bits.
▪ A set of screwdrivers:
▪ A small electrical-type flat-bladed screwdriver to unclip the CAT5 connectors from the pods.
▪ A tiny flat-bladed screwdriver to adjust the volume on the main hub.
▪ A socket set.
Suggested Extras:
▪ 3 m of self-adhesive ‘mini’ box trunking to secure the power cable.
▪ An extension cable in case the power supply is not within 1000 mm of the base of the CardioWall.
(CardioWalls are supplied, unless otherwise requested, with a power adaptor cable that extends
1000 mm from the base of the CardioWall.)
▪ Cleaning cloth and gentle cleaning spray.
Installation Heights:
▪ The CardioWall FreeStyle Duo units can be installed either at the same height as each other or
offset at different heights to accommodate both taller and shorter users.
▪ Take into consideration individual trampoline park primary user groups and the relative bounciness
of trampolines when determining the installation height.
▪ Recommended installation heights, measured from trampoline bed to bottom edge of unit:
A) Offset installations – lower unit: 1.20 m to 1.50 m; higher unit: 1.60 m to 2.0 m
B) Level installations – 1.60 m to 2.0 m
Age of Player
Recommended Height
(from trampoline bed to bottom
edge of the FreeStyle wall)
6 - 7 Years
120cm
8 - 9 Years
125 – 130cm
10 - 12 Years
130 – 140cm
12 - 14 Years
135 – 145cm
13 + Years
140 – 160cm
Recommended Trampoline Bed Size:
▪ Single trampoline: Frame approx. 2.4 m x 2.4 m (bed approx. 1.9 m x 1.9 m)
▪ Only one CardioWall FreeStyle unit should be installed per trampoline.
Operating Environment:
▪ Keep out of direct sunlight; bright sunlight can affect the LED pod sensors.
▪ Keep indoors and dry.
▪ Optimum ambient temperature: 5°C to 30°C. Avoid extreme fluctuations of temperature.