Figure 5
Tolérances dimensio3 mm [+1/8 po]
À moins d’indications contraires dans les spécifications
Sectionneur intégré
facultatif
17 1/4" ±3/16"
[439 ±5 mm]
À l’ouverture de câblage
sur place
1" 1/2"
[38 mm]
max
3 7/8" ±1/4"
98.4mm ±6mm
3 9/16" ±1/8"
90.2mm ±3mm
1" NPT
(For field wiring on heaters
with integral disconnect)
E
D
22 5/8" MAX.
(575mm)
10 11/16" ±3/16"
(271 ±5mm)
3 3/4"
(95.3mm)
A
G
1
3/
4"
±
1/
4"
(44
±
6m
m
)
8" ±1/4"
(203 ±6mm)
Ø5/8" (Ø15.5mm)
MOUNTING HOLES
(4 PLCS)
Optional Built-In
Disconnect Switch
17 1/4" ±3/16"
439mm ±5mm
To field wiring opening
1" NPT
(For remote room
thermostat, if applicable)
1 1/2" MAX.
(38mm)
Slim Junction Box
Optional Built-In
Thermostat
Filetage NPT de 25,4 mm (1 po)
(Pour un thermostat de pièce à
distance, le cas échéant)
9 1/4" ±1/4"
[235 ±6 mm]
Filetage NPT de 25,4 mm (1 po)
(Pour le câblage sur place des
appareils sans sectionneur intégré)
3 9/16" +1/8"
[90.2 mm +3 mm]
3 7/8" ±1/4"
98.4mm ±6mm
3 9/16" ±1/8"
90.2mm ±3mm
1" NPT
(For field wiring on heaters
with integral disconnect)
E
D
22 5/8" MAX.
(575mm)
10 11/16" ±3/16"
(271 ±5mm)
3 3/4"
(95.3mm)
A
G
1
3/
4"
±
1/
4"
(44
±
6m
m
)
8" ±1/4"
(203 ±6mm)
Ø5/8" (Ø15.5mm)
MOUNTING HOLES
(4 PLCS)
Optional Built-In
Disconnect Switch
17 1/4" ±3/16"
439mm ±5mm
To field wiring opening
1" NPT
(For remote room
thermostat, if applicable)
1 1/2" MAX.
(38mm)
Slim Junction Box
Optional Built-In
Thermostat
3 7/8" +1/4"
[98.4 mm +6 mm]
1" NPT
(Pour le câblage sur place des
appareils avec sectionneur intégré)
Filetage NPT de
25,4 mm (1 po)
(Pour un thermostat
de pièce à distance,
le cas échéant)
Thermostat
intégré facultatif
ø5/8" [ø15.5 mm]
Trous de montage
(4 plcs)
22 5/8"
(575 mm max.)
10 11/16"±3/16"
[271±5 mm]
8"±1/4"
[203±6 mm]
3"
±1
/4
"
[7
6 ±
6
m
m
]
3 3/4" (95.3 mm)
3 7/8" ±1/4"
98.4mm ±6mm
3 9/16" ±1/8"
90.2mm ±3mm
1" NPT
(For field wiring on heaters
with integral disconnect)
E
D
22 5/8" MAX.
(575mm)
10 11/16" ±3/16"
(271 ±5mm)
3 3/4"
(95.3mm)
A
G
1
3/
4"
±
1/
4"
(44
±
6m
m
)
8" ±1/4"
(203 ±6mm)
Ø5/8" (Ø15.5mm)
MOUNTING HOLES
(4 PLCS)
Optional Built-In
Disconnect Switch
17 1/4" ±3/16"
439mm ±5mm
To field wiring opening
1" NPT
(For remote room
thermostat, if applicable)
1 1/2" MAX.
(38mm)
Slim Junction Box
Optional Built-In
Thermostat
ø5/8"
[ø15.5 mm]
Trous de montage
(4 plcs)
22 5/8"
(575 mm max.)
10 11/16"±3/16"
[271±5 mm]
3 3/4" (95.3 mm)
1 3
/4
" ±
1/4
"
[4
4 ±
6
m
m
]
8"±1/4"
[203±6 mm]
Petite boîte à
bornes
Thermostat
intégré facultatif
Petit connecteur de commande
Grands connecteurs de commande
30
30
Ins
ta
lla
tio
n