![ruegg JUPITER 510 HK Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ruegg/jupiter-510-hk/jupiter-510-hk_installation-manual_1499073009.webp)
SMART-LINE
ECO-LINE
Installation Guide
9
VENUS K / HK
Open furnace
(EN 13229)
VENUS K / HK
Closed furnace
(EN 13229)
- Temperature at flue gas outlet
- Flue gas mass flow
- Minimum delivery pressure
- Nominal heat output
- Temperature at flue gas outlet
- Flue gas mass flow
- Flue gas outlet Ø
- Flue gas outlet Venus HK right/left Ø
- Minimum delivery pressure
- EN 13229 test condition no. A/A1
- EN 13229 test condition no. A1 with NHF
- VKF registration number
185° C
28.0 g/sec
10 Pa
7.0 kW
295° C
8.2 g/sec
180 mm
200 mm
14 Pa
RRF-29 01 24
RRF-29 01 22
12814