![ruegg JUPITER 510 HK Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ruegg/jupiter-510-hk/jupiter-510-hk_installation-manual_1499073015.webp)
SMART-LINE
ECO-LINE
Installation Guide
15
The appliance facing [12]/cowl [16] must also be pro-
tected by means of an insulation layer. Protection of
the facing is not required, if the open fireplace is de-
signed in a way that the free surfaces of the facing
and the surfaces of the recesses for storage of fuels
will not get hotter than 85° C . In case of surfaces
made of mineral construction materials, e.g. stove
tiles, except surfaces, on which objects can be placed,
the value of 85° C is replaced by a value of 120° C .
The increase of the maximum admissible temperature
of 85° C to 120° C only applies to more inclined or
vertical surfaces of the facing made of mineral con-
struction materials. This allows to design the facing as
heated tile wall or similar.
5.4. Brick lining
A mineral brick lining [6] with a thickness of 10 cm,
e.g. bricks, must be provided between the thermal in-
sulation layer [5] and the building wall [7]. The brick
lining must project beyond the connector by at least
20 cm.
The brick lining [6] is not necessary, if the building wall
[7]:
- has a thickness of at least 10 cm, and
- consists of non-combustible components, and
- is not a load-bearing concrete or reinforced concrete
wall.
The brick lining is to be implemented without joints
and over the entire gap of the facing.
Note: porous concrete is not suitable as mineral brick
lining!
5.5. Protection of the installation floor
Installation floors [10] with combustible construction
materials have to be protected as follows:
- by means of a concrete slab [9] with a thickness of
at least 10 cm, which has to be reinforced in case of
installation floors without sufficient lateral distribution
and a covering thermal insulation layer [8] as shown
in table.
Load-bearing concrete and reinforced concrete floors
have to be protected as follows:
- thermal insulation layer [8] as shown in table
NOTE:
For use of substitute insulation materials the manu-
facturer’s specifications apply!
8
c
m
s
e
e
t
a
b
le
Содержание JUPITER 510 HK
Страница 1: ...SMART LINE ECO LINE INSTALLATION GUIDE...
Страница 2: ......
Страница 26: ...SMART LINE ECO LINE Installation Guide 26 8 Mars 570 K with ceramic flue example with KMS system...
Страница 34: ...SMART LINE ECO LINE Installation Guide 34 Notes...
Страница 35: ...SMART LINE ECO LINE Installation Guide 35...
Страница 36: ...www ruegg cheminee com 89 90 00454 ma_smart line_en_rev2_07 2013...