Fan Assemblies
•
•
•
•
•
•
Fan assembly overview
The Ruckus ICX 7650 switch includes six redundant, hot-swappable fan assemblies. However, the switch is capable of running on one
power supply and five fans. The second power supply and sixth fan provide redundancy.
If the second power supply and sixth fan slots are unused, you must cover them with filler panels.
NOTE
Ruckus recommends that the Ruckus ICX 7650 switch operates with two power supplies and five fan assemblies installed. If a
power supply or fan assembly fails, it must be replaced as soon as possible.
The fan assemblies in the Ruckus ICX 7650 switch chassis can be removed and replaced without special tools. The device can continue
operating during the replacement.
The device supports the following types of fan assemblies:
•
Fan assembly with nonport-side air exhaust. This unit moves the air from the port-side to the nonport-side of the device.
•
Fan assembly supply with nonport-side air intake. This unit moves the air from the nonport-side to the port-side of the device.
FIGURE 35
Fan assembly
1
Captive screw
2
Fan assembly handle