DN 35-EN
13
MAINTENANCE
Before cleaning the dehumidifier, first ensure that the appliance is disconnected from the power
supply.
1) Outer case:
A) Wipe the shell with soft, slightly damp cloth.
B) If the dehumifier is very dirty, please use mild detergent then wipe off the detergent
with half dried cloth.
2) Air Filter cleaning:
The purpose of the air filter is to filter the dust or unclean material in the air. If the filter is
blocked by the dust the usage of the electricity will be greater tan normal. For the best
more efficient of removing moisture, plea- se clean the filter once in two weeks.
Cleaning Steps:
A.
Pull out the filter gently.
B. Clean the filter by vacuum
cleaner or washing with clean
wáter then dry the filter using
dry cloth.
SPECIFICATIONS
MODEL
RUBY DN 35-EN
POWER
220-240V ~ 50 Hz
MOISTURE REMOVAL
35 L/D (30°C 80% Hr)
POWER INPUT
600 W / 750 W
SIZE OF SHELL (H x W x D)
368*564*250 mm
WEIGHT
16 kg
OPERATING TEMPERATU- RE
5°C ~ 32°C / 5°C ~ 25°C
FUSE
3.15A/250V (PC BOARD)
GWP
R-290