Zeichnungen/Drawings • Seite/Page 7-5

7.5.  Ersatzteilliste  11528G

7.5.1. Allgemeine Teile

Best. Nr.

Beschreibung

Typ/Norm

Mechanische Teile

160036

Kunststoffschraube M 2,5 x 6

16006

Zylinderkopfschraube M 2 x 4

DIN 84

16096

Senkkopfschraube M 2 x 4

DIN 963

16083

Zylinderkopfschraube M 2,5 x 6

DIN 84

16074

Vierkant-Mutter M 2,5

16157

Schraube M 3 x 12DIN 966

16270

Silikonscheibe

16284

Mutter M 2,5

16424

Seitenblech

17861

Mutter M 3

17687

Gegenstecker 64 Pin

DIN 41612

163354**

Verriegelungsblock

16087

Senkkopfschraube M 2,5 x 6

DIN 965-A2

163353

Druckfeder für Verriegelung

163351

Mutternstück M 3

16009

Senkkopfschraube M 3 x 25

DIN 966-4.8

Allgemeine elektronische Teile

14610

AES/EBU-Übertrager

2-fach

19018

Transistor TIP 117

175623

Bargraph-Display 127 mm (5-Phasen)

Platinen

134992.1

Display-Treiber-Platine für 11528G

134961

Basis-Platine für 11528G

7.5.2. Display und Skala

Best. Nr.

Beschreibung

167028KIT

Service-Kit Skala (-60 bis +9 dB) schwarz, bestehend aus:
Skala, Skalenträgerblech und Tastensatz

167028

Sandwichskala (-60 bis +9 dB) schwarz RAL 9011

167027

Sandwichskala (-60 bis +9 dB) lichtgrau RAL 7035

129744

Frontpanel und Skala schwarz (-60 bis +9 dB) komplett

mit Display-Treiber-Platine

All manuals and user guides at all-guides.com

Содержание 11528G

Страница 1: ...Bedienungsanleitung Operating Manual Peakmeter 11528G All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...many Postfach P O box 71 06 54 50746 K ln Germany Internet www rtw de E Mail rtw rtw de WEEE Reg Nr Reg no DE 90666819 Kategorie Category 9 Ger teart Device type Diese Ger te erf llen als berwachungs...

Страница 3: ...nische Zeichnungen Im Anhang finden Sie die die vollst ndigen technischen Daten des Peakmeters und die CE Konformit tserkl rung Scope of this manual This manual is the operating handbook for the RTW P...

Страница 4: ...S ANSCHLUSS Dieses Symbol markiert einen Anschluss der mit leitenden Teilen des Messinstrumentes verbunden ist Stellen Sie sicher dass dieser Anschluss mit einem externen Schutzer dungs System verbund...

Страница 5: ...rung und Fehlersuche 3 1 3 1 Kalibrierung 3 1 3 2 nderung der Eingangsimpedanz 3 1 3 3 nderung der Ger teeinstellungen 3 1 3 3 1 Funktion der Drehcodierschalter 3 2 3 3 2 Funktion der DIP Schalter 3 2...

Страница 6: ...1 Abmessungen Mechanical outlines 7 1 7 2 Klemmverriegelung Quick fastening kit 7 2 7 3 Explosionsdarstellung Exploded view 7 3 7 4 Zubeh rkombinationen Accessory combination 7 4 7 5 Ersatzteilliste 7...

Страница 7: ...inem fein aufl senden Gas Plasma Display mit 201 Leuchtsegmenten je Bargraph zum einen ohne Zeitbewertung Sample Anzeige und zum anderen hellgesteuertda r berliegend mit der Zeitbewertung Integrations...

Страница 8: ...t denAnwender vor korruptem oder fehlendem digitalen Signal Funktionen Peakmeter mit Spitzenwertanzeige Im Normalbetrieb sind zweiAn zeige Varianten m glich Anzeige des Pegels ohne Bewertungszeit Samp...

Страница 9: ...rkiert ei nenAnschluss der elektrisch mit dem Referenzpunkt einer Schaltung verbunden ist und der f r die Erdung aus beliebigen funktionalen Gr nden mitAusnahme von Sicherheitsgr nden vorgesehen ist S...

Страница 10: ...V 26a AES EBU Ausgang bzw hei 26c 0 V 27a AES EBU Ausgang bzw kalt 27c Steuerausgang derzeit nicht genutzt 28a Steuerausgang derzeit nicht genutzt 28c Steuerausgang ERR Anzeige 29a Steuerausgang OVR A...

Страница 11: ...ruf des Speicherinhaltes ber die Taste Memo wird eine eventuell vorausgegan gene Nutzung der Gain Funktion ebenfalls signalisiert TASTE MEMO Diese Taste oder die gleichnamige externe Funktions wahl wi...

Страница 12: ...SS Anzeige Bild 1 2 Beispiel 2 oder einer mit 10 ms integrierten Peakanzeige Bild 1 2 Beispiel 1 Die Darstellung erfolgt in beiden F llen als zus tzlicher hellgesteuerter Bargraph ber dem normalhellen...

Страница 13: ...onen wenn derAussteuerungsmesser 11528G ab Serien Nr 1500 eingesetzt ist ZurAktivierung sind die Schalteing nge mit Pin 8 zu verbinden active low Die Schalteing nge liegen z T parallel gleichberechtig...

Страница 14: ...ten Die Sicherung ist bei einer Umschaltung entsprechend zu tauschen 220 240 V AC Betrieb 63 mA tr ge 110 120 V AC Betrieb 125 mA tr ge PH man Schalter Umschalter f r denAnzeige Modus nur 10 ms FAST S...

Страница 15: ...werden Die allgemein bekannten Schutzma nahmen zum Schutz des Ger tes vor statischen Entladungen ESD sind anzuwenden 3 3 nderung der Ger teeinstellungen Mittels der in Bild 3 1 dargestellten Hex Schal...

Страница 16: ...B FS 18 6 7 2 0 dB FS 17 7 8 3 0 dB FS 16 8 9 4 0 dB FS 15 9 A 5 0 dB FS 14 10 B 6 0 dB FS 13 11 C 7 0 dB FS 12 12 D 8 0 dB FS 11 13 E 9 0 dB FS 10 14 F 10 dB FS 9 15 3 3 2 Funktion der DIP Schalter S...

Страница 17: ...en Ende der horizontalen Skala Bereich des Korrelators auflegen und fest andr cken Skizze 1 Klebefolie mitsamt der horizontalen Skala an einer Ecke vorsichtig anheben und flach in Pfeilrichtung abzieh...

Страница 18: ...das Ger t mit Betriebsspannung und Eingangssignal 3 Stellen Sie fest ob zwischen Messpunkt A Referenzpunkt und Messpunkt B eine Spannung von 18 3 V DC anliegt Ein Fehlen dieser Spannung deutet auf ein...

Страница 19: ...den Austausch der Hauptplatine Bild 3 4 Beispielhafte Darstellung einer pulsbreitenmodulierten Signalform 7 Pr fen Sie mit einem Oszilloskop ob zwischen den Punkten A Referenzpunkt und I eine periodi...

Страница 20: ...Peakmeter Serie 11528G Seite 3 6 Kalibrierung und Fehlersuche All manuals and user guides at all guides com...

Страница 21: ...th once without any weighting sample precise display and once highlighted and super imposed with an integration time of 10 ms see Fig 4 2 example 1 Alternatively the sample precise peak level display...

Страница 22: ...LED gives a warning to the user in case of a corrupted or missing digital signal Functions Peak level display In normal operation two display modes are selectable level display without weighting sampl...

Страница 23: ...s manual or Operator manual for precautionary instructions FUNCTIONAL EARTH TERMINAL This symbol marks a terminal that is electrically connected to a reference point and is intended to be earthed for...

Страница 24: ...3a AES EBU input or hot 24a AES EBU input or cold 25a 0 V 26a AES EBU output or hot 26c 0 V 27a AES EBU output or cold 27c Control output n u 28a Control output n u 28c Control output ERR flag 29a Con...

Страница 25: ...he last memory reset MEMO KEY The use of this pushbutton or its equivalent external function recalls the highest level value the most negative correlation reading and a possible use of the gain mode s...

Страница 26: ...l be shown as a brighter bar on top of the normal unweighted sample level display However when the 10 ms only external function control see section 5 4 pin 16a is activated the L 10 ms slide switch se...

Страница 27: ...hing inputs only have these functions with a 11528G peakmeter serial no 1500 and above inserted For activating the switching inputs the corresponding pins have to be wired against pin 8 common potenti...

Страница 28: ...nect mains before switching Use the correct fuse value as defined 220 240 V AC operation 63 mA slow blow 110 120 V AC operation 125 mA slow blow PH man switch Switches the 10 ms only mode FAST switch...

Страница 29: ...When servicing it is very important to observe all standard ESD electrostatic discharge protection procedures 6 3 Setup changes Setup changes for overload detection can be achieved by the use of the...

Страница 30: ...2 dB FS 20 4 5 0 5 dB FS 19 5 6 1 0 dB FS 18 6 7 2 0 dB FS 17 7 8 3 0 dB FS 16 8 9 4 0 dB FS 15 9 A 5 0 dB FS 14 10 B 6 0 dB FS 13 11 C 7 0 dB FS 12 12 D 8 0 dB FS 11 13 E 9 0 dB FS 10 14 F 10 dB FS...

Страница 31: ...e selfadhesive tape onto the right end correlator side of the horizontal scale fig 1 Pull back the tape in direction of the arrow fig 2 The vertical scale can be seen now the unit is ready to be insta...

Страница 32: ...pcb component side 3 Measure for 18 3 V DC between point A reference and point B If this voltage is missing the power supply on the main circuit board is broken We recommend repair at the factory or...

Страница 33: ...between point A reference and point I The waveform should show a periodic pulse train If this waveform is faulty the processing on the main circuit board is broken We recommend repair at the factory...

Страница 34: ...Peakmeter 11528G Series Page 6 6 Calibration and Troubleshooting All manuals and user guides at all guides com...

Страница 35: ...9 6 5 1 0 7 s c r e w M 3 x 1 2 p i n 1 1 7 9 1 7 1 5 M 3 4 0 2 1 1 1 9 0 P i n 1 M 2 5 P P M G m o u n t i n g P P M G R m o u n t i n g F r o n t p a n e l c u t o u t 1 1 7 5 4 0 2 1 2 5 1 7 7 5 1...

Страница 36: ...p i n g l o c k f a s t e n i n g k i t O P T I O N C a t N o 1 3 9 7 3 U M R S T S A T Z K L E M M V E R R I E G E L U N G F R O N T P A N E L C U T O U T C O N N E C T O R P O S I T I O N N a m e R...

Страница 37: ...Peakmeter Serie 11528G Zeichnungen Drawings Seite Page 7 3 7 3 Explosionsdarstellung Exploded view All manuals and user guides at all guides com...

Страница 38: ...Program Meter 11528G Blend Einschubrahmen Cover plate and mounting frame 12996 60 x 210 mm 19 5HE Einschubrahmen 1125 10 mit 19 5U Subrack 1125 10 with Netzteil Power supply 2 XLR Buchsen connectors...

Страница 39: ...opfschraube M 2 5 x 6 DIN 965 A2 163353 Druckfeder f r Verriegelung 163351 Mutternst ck M 3 16009 Senkkopfschraube M 3 x 25 DIN 966 4 8 Allgemeine elektronische Teile 14610 AES EBU bertrager 2 fach 19...

Страница 40: ...w countersunk M 2 5 x 6 DIN 965 A2 163353 Spring for clamping device 163351 Nut M 3 for clamping lock block 16009 Screw countersunk M 3 x 25 DIN 966 4 8 Common electronical parts 14610 AES EBU transfo...

Страница 41: ...mo 1 Segment Gewicht ca 700 g 1 6 lbs netto Abmessungen 190 x 40 x 107 mm Anschluss 64 pol Federleiste nach DIN 41612A C Skala Skalenbereich 60 dB bis 9 dB Eingeblendete Skalenmarken 40 30 20 10 5 dB...

Страница 42: ...mpfindlichkeitssteigerung Memo Speicherabruf Reset Speicher l schen LED s Preemphase gelbe LED Gain rote LED Error rote LED Abtastrate zwei LED s Overload eine LED pro Kanal 10 ms rote LED lange Integ...

Страница 43: ...threshold DC filter OFF or 5 Hz Memory accuracy Memo 1 segment Weight approx 700 g 1 6 lbs net Dimensions 190 x 40 x 107 mm Connector 64 pin connector DIN 41612A C Scale Scale range 60 dB to 9 dB Bri...

Страница 44: ...y recall Reset memory reset LED s Emphasis yellow LED Gain red LED Error red LED Sample rate two LED s Overload one LED per channel 10 ms redLEDslowintegrationtime Slide switch L for loudness mode or...

Страница 45: ...as sich diese Erkl rung bezieht mit den folgenden Normen bzw normativen Dokumen ten bereinstimmt EMV 89 336 EWG EN 50081 1 M rz 1993 EN 55022 B gestrahlt EN 55022 B leitungsgef hrt EN 50082 1 EN 61000...

Страница 46: ...demonstrated to the following specifications as listed in the official journal of the European Communities EMC 89 336 EEC EN 50081 1 Emissions march 1993 EN 55022 Radiated Class B EN 55022 Conducted C...

Отзывы: